MAINDEC-10-SMFILE PAGE 1
IDENTIFICATION
--------------
PRODUCT CODE: AH - E522A - DD
DIAGNOSTIC CODE: MAINDEC - 10 - SMFILE (DSQDF)
PRODUCT NAME: DECSYSTEM 2020 DIAGNOSTICS FE-FILE PROGRAM
VERSION: 0.1
DATE RELEASED: MAY 1978
AUTHOR: JOHN R. KIRCHOFF
MAINTAINED BY: DIAGNOSTIC ENGINEERING GROUP
COPYRIGHT(C) 1978
DIGITAL EQUIPMENT CORPORATION
MARLBORO, MASS. 01752
THIS SOFTWARE IS FURNISHED UNDER A LICENSE FOR USE ONLY
ON A SINGLE COMPUTER SYSTEM AND MAY BE COPIED ONLY WITH
THE INCLUSION OF THE ABOVE COPYRIGHT NOTICE. THIS SOFTWARE,
OR ANY OTHER COPIES THEREOF, MAY NOT BE PROVIDED OR OTHERWISE
MADE AVAILABLE TO ANY OTHER PERSON EXECPT FOR USE ON SUCH SYSTEM
AND TO ONE WHO AGREES TO THESE LICENSE TERMS. TITLE TO AND
OWNERSHIP OF THE SOFTWARE SHALL AT ALL TIMES REMAIN IN DEC.
THE INFORMATION IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT
NOTICE AND SHOULD NOT BE CONSTRUED AS A COMMITMENT BY DIGITAL
EQUIPMENT CORPORATION.
DEC ASSUMES NO RESPONSIBILITY FOR THE USE OR RELIABILITY OF ITS
SOFTWARE ON EQUIPMENT WHICH IS NOT SUPPLIED BY DEC.
SMFILE - DECSYSTEM 2020 DIAGNOSTICS FE-FILE PROGRAM
DISK
----
THE SYSTEM DISK WILL CONTAIN A RESERVED (CONTIGUOUS) FE-FILE
AREA FOR THE 8080 CONSOLE PROCESSOR'S USE.
TOPS-20 -- <ROOT-DIRECTORY>BOOTSTRAP.BIN
TOPS-10 -- [6,2020]KS10FE.BIN
THIS FE-FILE AREA WILL CONTAIN THE KS-10 MICROCODE, THE SYSTEM
AND DIAGNOSTIC PRE-BOOTS AND BOOTSTRAPS, THE BOOTCHECK 1 MICROCODE,
THE BOOTCHECK 2 DIAGNOSTIC CODE, AND 247 [0-366(8)] FRONT-END
INDIRECT 8080 COMMAND FILES.
THIS AREA WILL BE POINTER TO BY WORDS IN THE HOME BLOCK. THERE
WILL BE THREE WORDS USED IN THE HOME BLOCK. WORD 1 PROVIDES THE DISK
ADDRESS OF THE FE-FILE AREA. WORD 2 PROVIDES THE LENGTH OF THE FE-FILE
AREA. WORD 3 PROVIDES THE 8080 FORMAT TRACK/CYLINDER/SECTOR ADDRESS.
HOME BLOCK
----------
I
I---------
101 I DISK ADDRESS OF FE-FILE AREA (SECTOR #)
I---------
102 I LENGTH (# OF SECTORS)
I---------
103 I 8080 TRACK/CYL/SECTOR
I---------
I
----------
THE 8080 TRACK/CYLINDER/SECTOR WORD WILL BE AS FOLLOWS:
3-11 23-27 31-35
------------------------------------------------------
I 000 I I 0'S I I 000 I I
------------------------------------------------------
^ ^ ^
I I I
CYLINDER TRACK SECTOR
SMFILE - DECSYSTEM 2020 DIAGNOSTICS FE-FILE PROGRAM
THE FIRST PAGE IN THE FE-FILE AREA WILL BE USED AS AN 8080
DIRECTORY TO CONTAIN PHYSICAL DISK ADDRESSES AND LENGTHS FOR THE
ASSOCIATED FILES CONTAINED WITHIN THE REMAINDER OF THE FE-FILE AREA.
THE POINTER WORDS WILL BE IN THE 8080 TRACK/CYL/SECTOR FORMAT
AND THE PAGE ##,,LENGTH WORD WILL BE IN THE STARTING PAGE NUMBER IN THE
FILE AND THE NUMBER OF 512 WORD PAGES.
THIS FILE WILL BE AS FOLLOWS:
FE-FILE PAGE 0
--------------
WORD 0 I POINTER TO FREE SPACE
1 I PAGE #,,LENGTH
I-------------
2 I POINTER TO MICROCODE
3 I PAGE #,,LENGTH
I-------------
4 I POINTER TO MONITOR PRE-BOOT
5 I PAGE #,,LENGTH
I-------------
6 I POINTER TO DIAGNOSTIC PRE-BOOT
7 I PAGE #,,LENGTH
I-------------
10 I POINTER TO BOOTCHECK 1 MICROCODE
11 I PAGE #,,LENGTH
I-------------
12 I POINTER TO BOOTCHECK 2 PRE-BOOT
13 I PAGE #,,LENGTH
I-------------
14 I POINTER TO MONITOR BOOT
15 I PAGE #,,LENGTH
I-------------
16 I POINTER TO DIAGNOSTIC BOOT
17 I PAGE #,,LENGTH
I-------------
20 I POINTER TO BOOTCHECK 2
21 I PAGE #,,LENGTH
I-------------
22 I POINTER TO INDIRECT FILE 0
23 I PAGE #,,LENGTH
I-------------
24 I POINTER TO INDIRECT FILE 1
25 I PAGE #,,LENGTH
I-------------
/ ...
I-------------
776 I POINTER TO INDIRECT FILE 366(8)
777 I PAGE #,,LENGTH
--------------
SMFILE - DECSYSTEM 2020 DIAGNOSTICS FE-FILE PROGRAM
--------------
PAGE 1 I
I MICROCODE - 12 PAGES
I
--------------
--------------
PAGE 13 I
I MONITOR PRE-BOOT - 1 PAGE
I
--------------
--------------
PAGE 14 I
I DIAGNOSTICS PRE-BOOT - 1 PAGE
I
--------------
--------------
PAGE 15 I
I BOOTCHECK 1 MICROCODE - 12 PAGES
I
--------------
--------------
PAGE 27 I
I BOOTCHECK 2 PRE-BOOT - 1 PAGE
I
--------------
I
/
I
--------------
LAST PAGE I
I
I
--------------
FREE SPACE STARTS AT PAGE 28 ON "RESET" WITH THE BOOTS AND OTHER
FILES ASSIGNED SPACE AS APPROPRIATE.
THE FREE SPACE POINTER STARTS WITH THE PAGE #,,LENGTH WORD EQUAL
TO (^D28,,<LENGTH FROM HOME BLOCK 102 - ^D28>).
SMFILE - DECSYSTEM 2020 DIAGNOSTICS FE-FILE PROGRAM
THE SMFILE PROGRAM WILL HAVE THE FOLLOWING COMMANDS TO GENERATE
AND MAINTAIN THE FE-FILE SYSTEM:
1. DEPOSIT (BC1,CRAM)
2. DEBUG (CLEAR,SET)
3. ECHO (YES,NO)
4. EXAMINE (BC1,CRAM)
5. EXIT
6. HELP
7. INFORMATION (DISK,FEFILE,FREE,INDIRECT)
8. OUTPUT (BC1,CRAM,MTBOOT,RAM)
9. PUSH
10. RDBC1 ("FILE.EXT")
11. READ ("FILE.EXT")
12. SERIAL "NUMBER"
13. TAKE ("FILE.EXT")
14. TYPE (INDIRECT) (0-366(8))
15. WRITE (BC1,BC2,BOOT,CRAM,DIAGBT,DONE,INDIRECT,RESET,SETUP)
SMFILE - DECSYSTEM 2020 DIAGNOSTICS FE-FILE PROGRAM
THE WRITE COMMAND WILL HAVE THE FOLLOWING ARGUMENTS:
A. BC1
B. BC2 "FILE"
C. BOOT "FILE"
D. CRAM
E. DIAGBT "FILE"
F. INDIRECT "0-366(8)" "FILE"
G. RESET
H. SETUP "DEV:"
I. DONE
THE OUTPUT COMMAND WILL HAVE THE FOLLOWING ARGUMENTS:
A. BC1 "FILE".RAM
B. CRAM "FILE".RAM
C. RAM "FILE".RAM
D. MTBOOT "INPUT".EXE AS "MTBOOT".RDI
SMFILE - DECSYSTEM 2020 DIAGNOSTICS FE-FILE PROGRAM
AN EXAMPLE SET OF COMMANDS NECESSARY TO CREAT THE FRONT-END
FILE SYSTEM ON DISK FOR THE DECSYSTEM 2020:
@RUN SMFILE
DECSYSTEM-2020 FE-FILE PROGRAM
VERSION #.#
[FOR HELP TYPE "HELP"]
SMFILE>WRITE SETUP DEV:
SMFILE>WRITE RESET
SMFILE>READ KS10.ULD
SMFILE>SERIAL ####
SMFILE>WRITE CRAM
SMFILE>WRITE BOOT SMBOOT.EXE
SMFILE>WRITE DIAGBT SMMON.EXE
SMFILE>WRITE DONE
SMFILE>EXIT
AN EXAMPLE PROCEDURE FOR CREATING THE MICROCODE AND READ-IN
FILE TO BE THEN COPIED ONTO THE FRONT OF THE "SYSTEM" MAGTAPE FOR
MAGTAPE BOOTING:
@RUN SMFILE
DECSYSTEM-2020 FE-FILE PROGRAM
VERSION #.#
[FOR HELP TYPE "HELP"
SMFILE>READ KS10.ULD
SMFILE>OUTPUT CRAM KS10.RAM
SMFILE>OUTPUT MTBOOT MTBOOT.EXE AS MTBOOT.RDI
SMFILE>EXIT
SMFILE - DECSYSTEM 2020 DIAGNOSTICS FE-FILE PROGRAM
THE FRONT-END INDIRECT FILES CONTAIN FRONT-END MICRO-PROCESSOR
COMMANDS THAT ARE USED AS IF THE USER HAD TYPED THEM DIRECTLY. SEVERAL
COMMANDS MAY BE PUT ON A SINGLE LINE WITH COMMANDS SEPARATED BY COMMAS.
A COMMAND LINE MAY BE UP TO 80 CHARACTERS LONG. THE INDIRECT FILE MAY
CONTAIN MANY LINES OF COMMANDS WITH THE FILE BEING LIMITED TO A MAXIMUM
OF 2047(10) CHARACTERS. THE INPUT FILE USED TO CREATE THE FRONT-END
INDIRECT FILE WILL CONTAIN CR/LF PAIRS TO END LINES BUT THESE WILL BE
STRIPPED TO CR ONLY IN THE INDIRECT FILE.
THE BYTES OF THE INDIRECT FILE WILL BE ARRANGED INTO THE
FOLLOWING FORMAT TO FACILIATE THEIR USE BY THE FRONT-END MICRO-
PROCESSOR:
0-3 4-11 12-19 20-27 28-35
---------------------------------------------
I 0000 I CHAR 4 I CHAR 3 I CHAR 2 I CHAR 1 I
---------------------------------------------
I 0000 I CHAR 8 I CHAR 7 I CHAR 6 I CHAR 5 I
---------------------------------------------
I /----/ I
---------------------------------------------
I 0000 I 0 BYTE I CHAR Z I CHAR Y I CHAR X I
---------------------------------------------
THE FRONT-END INDIRECT FILE WILL TERMINATE WITH A ZERO BYTE.
SMFILE - DECSYSTEM 2020 DIAGNOSTICS FE-FILE PROGRAM
THE FOLLOWING HALT ADDRESSES DURING THE DISK PRE-BOOT
OPERATION INDICATE THE FOLLOWING FAILURES:
HALT 1001 - TRIED TO OVERLOAD PRE-BOOT
HALT 1002 - DISK RETRY FAILURE
HALT 1003 - NO RH-11 BASE ADDRESS
THE FOLLOWING HALT STATUS BLOCK IS SAVED IF THE DISK
PRE-BOOT FAILS:
LOC 100 - 8080 DISK ADDRESS
LOC 101 - MEMORY PAGE ADDRESS
LOC 102 - T3, SELECTION PICKUP POINTER
LOC 103 - RPCS1, CONTROL AND STATUS 1 REG
LOC 104 - RPCS10, CONTROL AND STATUS 2 REG
LOC 105 - RPDS, DRIVE STATUS REG
LOC 106 - RPER1, ERROR 1 REG
LOC 107 - RPER2, ERROR 2 REG
LOC 110 - RPER3, ERROR 3 REG
LOC 111 - UBA PAGING RAM LOCATION 0
LOC 112 - UBA STATUS REG
LOC 113 - PRE-BOOT VERSION
THE FOLLOWING HALT ADDRESSES DURING THE MAGTAPE PRE-BOOT
OPERATION INDICATE THE FOLLOWING FAILURES:
HALT 1001 - TRIED TO OVERLOAD PRE-BOOT
HALT 1002 - MAGTAPE READ ERROR
HALT 1003 - NO RH-11 BASE ADDRESS
HALT 1004 - MAGTAPE SKIP EOF ERROR
THE FOLLOWING HALT STATUS BLOCK IS SAVED IF THE MAGTAPE
PRE-BOOT FAILS:
LOC 100 - 0
LOC 101 - MEMORY PAGE ADDRESS
LOC 102 - T3, SLECECTION PICKUP POINTER
LOC 103 - MTCS1, CONTROL AND STATUS 1 REG
LOC 104 - MTCS2, CONTROL AND STATUS 2 REG
LOC 105 - MTDS, DRIVE STATUS REG
LOC 106 - MTER, ERROR REG
LOC 107 - 0
LOC 110 - 0
LOC 111 - UBA PAGING RAM LOCATION 0
LOC 112 - UBA STATUS REG
LOC 113 - PRE-BOOT VERSION
[END]