Trailing-Edge
-
PDP-10 Archives
-
bb-h137e-bm_tops20_v6_1_instl
-
new-subsys/sprret.spe
There are 31 other files named sprret.spe in the archive. Click here to see a list.
First used in SPEAR 1.1 -- written 22-June-81
Template blocks for Full style RFB blocks
@@002 FULL TEMPL
TIME OF OCCURRENCE \
@@010 FULL TEMPL
DIAGNOSTIC \ VERSION \
USER PPN: \
@@011 FULL TEMPL
FAILED AT TEST \ \
@@011.1 FULL TEMPL
SUCCEEDED \
@@012 FULL TEMPL
LAST STATUS WAS ON \
CONNECTS SINCE CONNECTS SINCE
PORT/NODE LAST ENTRY STARTED
@@013 FULL TEMPL
\> / \> \>>>>>> \>>>>>>
@@014 FULL TEMPL
MESSAGE: \
@@100.1 FULL TEMPL
CI20 \
@@100.2 FULL TEMPL
CI20 Forced \ \
@@100.3 FULL TEMPL
NIA20 \
@@100.4 FULL TEMPL
NIA20 Forced \ \
@@101.1 FULL TEMPL
CI20 INFORMATION
CSR REG \00000,,000000 \
UCODE VERSION \>>>>>>>>>>>
UCODE \
CRAM ADDRESS \000/ \0000 \0000 \0000 \0000
@@101.2 FULL TEMPL
CI20 INFORMATION
CSR REG \00000,,000000 \
UCODE VERSION \>>>>>>>>>>>
UCODE \
CRAM ADDRESS \000 \
@@101.3 FULL TEMPL
NIA20 INFORMATION
CSR REG \00000,,000000 \
UCODE VERSION \>>>>>>>>>>>
UCODE \
CRAM ADDRESS \000/ \0000 \0000 \0000 \0000
@@101.4 FULL TEMPL
NIA20 INFORMATION
CSR REG \00000,,000000 \
UCODE VERSION \>>>>>>>>>>>
UCODE \
CRAM ADDRESS \000 \
@@102 FULL TEMPL
CHANNEL INFORMATION
STATUS WORD 0 \00000,,000000
CW 1 \00000,,000000
STATUS WORD 1 \00000,,000000 \
STATUS WORD 2 \00000,,000000
@@110 FULL TEMPL
COMMON DATA
COMMAND REF #: \0000000 HOST COMMAND #: \
CI20 PORT #: \>>>>>
NODE #: \>>>>>
SEQUENCE #: \>>>>>
FORMAT: \0 \
FLAGS: \0 \
EVENT: \000 \
CNTLR DEVICE #: \000\0000000
CNTLR CLASS: \0 \
CNTLR MODEL: \0 \
CNTLR SOFTWARE VER: \0
CNTLR HARDWARE VER: \0
@@112 FULL TEMPL
HOST MEMORY ERROR DATA
HOST MEM ADDR: \00000,,000000
@@103 FULL TEMPL
KLIPA Channel: \<
Reason for Counter gathers: \
CI node: \
Individual Counters:
PATH A ACK: \
PATH A NAK: \
PATH A NO RESP: \
PATH B ACK: \
PATH B NAK: \
PATH B NO RESP: \
DATAGRAMS DISCARDED: \
PACKETS TRANSMITTED: \
PACKETS RECEIVED: \
CRC ERRORS ON PACKETS: \
MOVER PARITY ERRORS: \
CBUS PARITY ERRORS: \
REGISTER PLIPE ERRORS: \
DATA PLIPE ERRORS: \
CHANNEL ERRORS: \
EBUS PARITY ERRORS: \
SPURIOUS CHANNEL ERRORS: \
CBUS AVAILABLE TIMEOUTS: \
SPURIOUS RECEIVE ATTENTIONS: \
SPURIOUS TRANSMIT ATTENTIONS: \
TRANSMIT BUFFER PAR ERRORS: \
TRANSMIT TIMEOUTS: \
@@113 FULL TEMPL
UNIT IDENTIFICATION DATA
UNIT NUMBER: \>>>>>
MULTI-UNIT CODE: \000
UNIT DEVICE #: \000\0000000
UNIT CLASS: \0 \
UNIT MODEL: \0 \
UNIT SOFTWARE VER: \0
UNIT HARDWARE VER: \0
VOLUME S/N: \0000000
@@114 FULL TEMPL
DISK TRANSFER DATA
LEVEL: \>>>
RETRY: \>>>
HEADER: \0000000 \
BLOCK AT ERROR WAS \
@@115 FULL TEMPL
SDI DATA
HEADER: \0000000 \
BLOCK AT ERROR WAS \
CONTROLLER DATA
REQUEST BYTE: \0 \
MODE BYTE: \0 \
ERROR BYTE: \0 \
CONTROLLER BYTE: \0
RETRY COUNT / FAILURE CODE: \0
@@116 FULL TEMPL
UNKNOWN DEVICE DATA
GET STATUS BYTES 11-8: \0000000
15-12: \0000000
@@116.1 FULL TEMPL
RA80/81 DEVICE DATA
LAST POSITION COMMAND: \0
SDI ERROR STATUS: \0 \
LAST SEEK CYLINDER: \0\0
HEAD NUMBER: \>>
MICROPROCESSOR LEDS: \0 \
FRONT PANEL FAULT CODE: \0 \
@@116.4 FULL TEMPL
RA60 DEVICE DATA
PREVIOUS CYLINDER: \000
PREVIOUS HEAD NUMBER: \>>
CURRENT CYLINDER: \000
CURRENT HEAD NUMBER: \>>
ERROR CODE: \0
@@117 FULL TEMPL
SMALL DISK DATA
CYLINDER: \>>>>>
@@120 FULL TEMPL
BYTES \-\ \00 \00 \00 \00 (\0)
@@120.7 FULL TEMPL
UNDEFINED DATA IN 8 BIT OCTAL BYTES
(UNUSED RIGHT 4 BITS IN 36-BIT WORD)
@@121 FULL TEMPL
MSCP STATUS (HEX): \00000000
@@122.7 FULL TEMPL
UNTRANSLATED DATA IN 8 BIT OCTAL BYTES
(UNUSED RIGHT 4 BITS IN 36-BIT WORD)
@@123.7 FULL TEMPL
EXTRANEOUS DATA IN 8 BIT OCTAL BYTES
(UNUSED RIGHT 4 BITS IN 36-BIT WORD)
@@200 FULL TEMPL
COMMON DATA
COMMAND REF #: \0000000 HOST COMMAND #: \
CI20 PORT #: \>>>>>
NODE #: \>>>>>
MEDIA ID: \00000,,000000 \
BLOCKS READ: \>>>>>>>>>>
BLOCKS WRITTEN: \>>>>>>>>>>
POSITION AT ERR 1: \>>>>>>>>>>
POSITION AT ERR 2: \>>>>>>>>>>
UNIT NUMBER: \>>>>>
ENDCODE: \0 \
FLAGS: \0 \
STATUS: \000 \
@@201 FULL TEMPL
READ OR WRITE COMMAND DATA
BYTE COUNT: \>>>>>>>>>>
FIRST BAD BLOCK: \>>>>>>>>>>
@@
Template blocks for Short style RFB blocks
@@010 SHORT TEMPL
DIAGNOSTIC \ V\, RUN BY PPN: \
@@011 SHORT TEMPL
FAILED TEST \ \
@@011.1 SHORT TEMPL
SUCCEEDED \
@@012 SHORT TEMPL
LAST STATUS WAS ON \
@@014 SHORT TEMPL
MESSAGE: \
@@100.1 SHORT TEMPL
CI20 \
@@100.2 SHORT TEMPL
CI20 Forced \ \
@@100.3 SHORT TEMPL
NIA20 \
@@100.4 SHORT TEMPL
NIA20 Forced \ \
@@101.1 SHORT TEMPL
CSR: \00000,,000000 CRAM ADDRESS: \000=\0000 \0000 \0000 \0000
UCODE \ \@
@@101.2 SHORT TEMPL
CSR: \00000,,000000 CRAM ADDRESS: \000
UCODE \ \@
@@101.3 SHORT TEMPL
CSR: \00000,,000000 CRAM ADDRESS: \000=\0000 \0000 \0000 \0000
UCODE \ \@
@@101.4 SHORT TEMPL
CSR: \00000,,000000 CRAM ADDRESS: \000
UCODE \ \@
@@102 SHORT TEMPL
PORT ERROR WORD: \000000,,000000
@@103 SHORT TEMPL
Counters on KLIPA channel # \< reason:\
@@110 SHORT TEMPL
HSC50 Error Message Node \ \
@@113 SHORT TEMPL
on \ #\ S/N \ \@
@@114 SHORT TEMPL
at \ \ \@
@@115 SHORT TEMPL
SDI Error - \ - \@
@@116 SHORT TEMPL
@@116.1 SHORT TEMPL
\ - \ - \
@@116.4 SHORT TEMPL
ERROR CODE: \
@@120.7 SHORT TEMPL
@@121 SHORT TEMPL
MSCP ERROR - MSCP STATUS (HEX)=\00000000
@@122.7 SHORT TEMPL
@@123.7 SHORT TEMPL
@@200 SHORT TEMPL
HSC50 End Message Node \ \: Unit \ \ \@
@@
The following messages are for DECNET Phase IV "Event
Logging Message" translation.
@@SHORT UNKNOWN FUNCTION CODE
DECNET Function Code ## -- ## bytes (No translation)
@@UNKNOWN FUNCTION CODE
No translation available for Function Code ##
Dump of ## data bytes in octal & decimal:
octal decimal
@@REMAINING BYTE DUMP
%%%% %%%%
@@SHORT DECNET TEXT
##
@@DECNET TEXT
##
@@DECNET PARAMS
##
@@
***** End of DECNET Phase IV messages! *****
@@PACKET SUMMARY
SPEAR Version ##. Retrieval from ##
Report generated ##
As directed by ##
Report sent to ##
@@PACKET WARNING
*** Warning (TOPS-10 only) ***
The original event file (from which the packet file was derived) must
exist in the original directory. Otherwise, the RETRIEVE output will be
incorrect.
@@OVERALL SUMMARY
SPEAR Version ##. Retrieval from ##
Report generated ##
As directed by ##
Selected window: ## to ##.
Selected records are ##
Selection type is ##
Report sent to ##
@@SHORT DATE
SEQ TIME \
@@SHORT HEAD
\ \ \@
@@FULL HEAD
***********************************************
##
LOGGED ON ## MONITOR UPTIME WAS ##
DETECTED ON SYSTEM # ##
RECORD SEQUENCE NUMBER: ##
***********************************************
@@SHORT 114
STATS DRIVE: ##, VOLID: ##, REASON: ##.
@@COMMON 114
Volume ID: ## Reason recorded: ##
Channel info(##): ## # ## on PI level ##
Device info(##): ##, ## ## PIA: ##
READS WRITES ##
TOTAL : %%%%%%%%%% %%%%%%%%%% %%%%%%%%%%
@@TAPE 114
NRZI : %%%%%%%%%% %%%%%%%%%%
PE : %%%%%%%%%% %%%%%%%%%%
GCR : %%%%%%%%%% %%%%%%%%%%
@@SHORT 246
HSC50 Out Of Band Message KLIPA Chn: ## HSC50 Node: ##
HSC50 Name: ##
Message: ##
@@COMMON 246
KLIPA Chn: ##
HSC50 Node: ##
HSC50 Name: ##
Message: ##
@@01_00
Extended sense data not updated
@@01_01
Extended sense data updated and contains something of interest
@@03_01
Command was issued with tape at BOT
@@03_02
Saw BOT indicator after tape motion started
@@03_03
ARA ID detected
@@11_01
TU is on-line but not ready (Possible when TU is manually rewound
or loading)
@@11_02
Fatal error has occurred and this command cannot be performed until
error status has been presented and a TM CLEAR received
@@11_03
Access to TU is allowed but TU is either rewinding or doing a DSE
from another MASSBUS or keypad command
@@15_01
No record found within 25 ft(7.6 m) of tape
@@15_02
ID Burst neither PE or GCR
@@15_03
ARA ID not found
@@15_04
No GAP found after ID Burst (PE) or ARA ID Burst (GCR)
@@20_00
Extended sense data not updated
@@20_01
Extended sense data updated and contains something of interest
@@21_00
Extended sense data not updated
@@21_01
Extended sense data updated and contains something of interest
@@22_01
CRC error, ACRC error, pointer mismatch, uncorrectable or two track
error set in ECCSTA register (This code generated by write GCR
operations)
@@22_02
CRC error, ACRC error, or uncorrectable set in ECCSTA register
(This code generated by read GCR operations)
@@22_03
Uncorrectable error set in ECCSTA register (This code generated
by read PE operations)
@@22_04
AMTIE, pointer mismatch, uncorrectable, two track error or single
track error set in ECCSTA register (This code generated by write PE
operations)
@@22_05
At least one bit set in ECCSTA register
@@22_06
At least one Write Fail bit set in RPFAIL and RPATH registers
(This code generated by write PE operations)
@@22_07
More than one Write Fail bit set in RPFAIL and RPATH registers
(This code generated by write GCR operations)
@@22_10
RSTAT contains bad code
@@22_11
CRC characters from WMC and RMC do not match (This code generated
by write PE operations)
@@22_12
MASSBUS data bus parity error
@@22_13
Record length incorrect during retry opposite attempt: invalid data
has been transferred
@@30_01
Illegal command code
@@30_02
Data transfer command issued while non-data transfer command in
progress on same tape unit
@@30_03
WMC error; check Encode register for reason. May be Illegal Format
or Skip Count codes
@@30_04
RUN not received`from MASSBUS controller
@@30_05
Command read from RMC register RCMLP did!not match command loaded
into RCMD register (This code generated in selected function
routine)
@@30_06
ECC ROM parity error
@@30_07
XMC ROM parity error
@@30_10
Command read from RMC register RCMLP did not match command loaded
into RCMD register (This code glnerated when Verify ID Burst
command loaded during write of BOT area)
@@30_11
Command read from RMC register RCMLP did not match command loaded
into RCMD register (This code generated when Verify ARA Burst
command loaded during write of BOT area)
@@30_12
Command read from RMC register RCMDP did not match command loaded
into RCMD register (This code generated when Verify ARA ID command
loaded during write of BOT area)
@@30_13
Command read from RMC register RCMLP did not match command loaded
into RCMD register (This code generated when Verify Gap command
loaded during write of BOT area)
@@30_14
Command read from RMC register RCMLP did not match command loaded
into RCMD register (This code generated when Read ID Burst command
loaded during read of BOT area)
@@30_15
Command read from RMC register RCMLP did not match command loaded
into RCMD register (This code generated when Verify ARA ID command
loaded during read of BOT area)
@@30_16
Command read from RMC register RCMLP did not match command loaded
into RCMD register (This code generated when Verify Gap command
loaded during read of BOT area)
@@30_17
Command read from RMC register RCMLP did not match command loaded
into RCMD register (This code generated when Find Gap command
loaded during Erase Gap routine)
@@30_20
WMC LEFT failed to set in Extended Sense routine
@@30_21
XL PE set in INTSTA register
@@30_22
XMC DONE did not set
@@30_23
WMC ROM PE or RD PE set in WMCERR register
@@31_01
TU Status parity error
@@31_02
TU Command parity error
@@31_03
Rewinding tape went off-line
@@31_04
Tape went not ready during DSE
@@31_05
TU CMD status changed during DSE
@@31_06
TU velocity never came up to speed
@@31_07
TU velocity changed after up to speed and writing started
@@31_10
TU CMD did not load correctly to start tape motion in selected
function routine
@@31_11
TU CMD did not load correctly to set drive density
@@31_12
TU CMD did not load correctly to set drive density
@@31_13
TU CMD did not load correctly to set drive density
@@31_14
Failed to write density ID Burst correctly
@@31_15
Failed to write ARA Burst correctly
@@31_16
Failed to write ARA ID correctly
@@31_17
ARA error bit set in MTA Status B register
@@31_20
unknown
@@31_21
Could not find a gap after the ID code was written correctly
@@31_22
TU CMD did not load correctly to start tape motion to read ID Burst
@@31_23
Time-out looking for BOT after detecting ARA ID Burst
@@31_24
Failed to write Tape Mark correctly
@@31_25
Tape never came up to speed while trying to reposition for retry of
writing Tape Mark
@@31_26
TU CMD did not load correctly to start tape motion in Erase Gap
routine
@@31_27
Could not detect a gap in Erase Gap routine
@@31_30
Could not detect a gap after writing record
@@31_31
Read path terminated before entire record was written
@@31_32
Could not find a gap after writing record and read path terminated
early
@@31_33
TU CMD did not load correctly to backup for retry of Write Tape Mark
@@31_34
TU Velocity changed after up to speed while trying to reposition
for retry of writing Tape Mark
@@31_35
TU CMD did not load correctly to backup to retry a read of BOT ID
@@31_36
Time-out looking for BOT after failing to write BOT ID
@@31_37
TU velocity changed while writing PE gap before starting to write
record
@@31_40
TU CMD did not load correctly to set PE tape density at start of
write BOT ID Burst
@@31_41
TU CMD did not load correctly to set GCR tape density after writing
Density ID
@@31_42
TU CMD did not load correctly to set PE tape density at start of
read from BOT
@@31_43
TU CMD did not load correctly to set GCR tape density after reading
a GCR Density ID Burst
@@32_00
RST0 interrupt occurred with TM RDY still set
@@32_01
Power failed to interrupt
@@32_02
Interrupt for unknown readon on channel 5.5
@@32_03
Interrupt for unknown readon on channel 6.5
@@32_04
Interrupt for unknown readon on channel 7
@@32_05
05 Interrupt for unknown readon on channel 7.5
@@32_06
CAS contention retry count expired
@@32_07
CAS Contention error not retryable
@@32_10
Queue error; could not find queue entry
@@32_11
Queue entry already full
@@32_12
8085 ROM parity error
@@32_13
In-line test 0; WMC self test failed = M8959-M8957
@@32_14
In-line test 1; XMC ROM parity error M8958-M8959-M8960
@@32_15
In-line test 2; RPM self test failed M8953-M8960
@@32_16
In-line test 3; RPM1 channel 0 self test failure M8950 (slot AB12)
@@32_!7
In-line ueSt 4; RPM1 channel 1 self test failure M8950 (slot AB13)
@@32_20
In-line test 5; RPM1 channel 2 self test failure M8950 (slot AB14)
@@32_21
In-line test 6; RPM1 channel 3 self test failure M8950 (slot AB15)
@@32_22
In-line test 7; RPM1 channel 4 self test failure M8950 (slot AB16)
@@32_23
In-line test 10; RPM1 channel 5 self test failure M8950 (slot CD13)
@@32_24
In-line test 11; RPM1 channel 6 self test failure M8950 (slot CD14)
@@32_25
In-line test 12; RPM1 channel 7 self test failure M8950 (slot CD15)
@@32_26
In-line test 13; RPM1 channel P self test failure M8950 (slot CD16)
@@32_27
In-line test 14; RPM1 error correction self test M8950-M8951-M8953
@@32_30
In-line test 15; 40000-40777 RAM memory failure M8960
@@32_31
In-line test 16; 41000-41777 RAM memory failure M8960
@@32_32
In-line test 17; 42000-42777 RAM memory failure M8960
@@32_33
In-line test 20; 43000-43777 RAM memory failure M8960
@@32_34
In-line test 21; 44000-44777 RAM memory failure M8960
@@32_35
In-line test 22; 45000-45777 RAM memory failure M8960
@@32_36
In-line test 23; 46000-46777 RAM memory failure M8960
@@32_37
In-line test 24; 47000-47777 RAM memory failure M8960
@@32_40
In-line test 25; loop write to read at TU port 0 - GCR
@@32_41
In-line test 26; loop write to read at TU port 0 - PE
@@32_42
In-line test 27; loop write to read at TU port 1 - GCR
@@32_43
In-line test 30; loop write to read at TU port 1 - PE
@@32_44
In-line test 31; loop write to read at TU port 2 - GCR
@@32_45
In-line test 32; loop write to read at TU port 2 - PE
@@32_46
In-line test 33; loop write to read at TU port 3 - GCR
@@32_47
In-line test 34; loop write to read at TU port 3 - PE
@@32_50
In-line test 35; loop write to read at MTA 0 - GCR
@@32_51
In-line test 36; loop write to read at MTA 0 - PE
@@32_52
In-line test 37; loop write to read at MTA 1 - GCR
@@32_53
In-line test 40; loop write to read at MTA 1 - PE
@@32_54
In-line test 41; loop write to read at MTA 2 - GCR
@@32_55
In-line test 42; loop write to read at MTA 2 - PE
@@32_56
In-line test 43; loop write to read at MTA 3 - GCR
@@32_57
In-line test 44; loop write to read at MTA 3 - PE
@@34_01
Control bus parity error
@@34_02
Illegal register referenced
@@77_01
Keypad entry error
@@77_02
TM78 not off-line
@@77_03
Illegal instruction code
@@77_04
Microdiagnostic start or continue command issued
@@77_05
Microdiagnostic loop on error command issued
@@UNKNOWN TU78
UNEXPECTED combination -- interrupt code: ##
failure code: ##
@@
First used in SPEAR 1.1 -- written 22-June-81
Template blocks for Full style RFB blocks
@@002 FULL TEMPL
TIME OF OCCURRENCE \
@@010 FULL TEMPL
DIAGNOSTIC \ VERSION \
USER PPN: \
@@011 FULL TEMPL
FAILED AT TEST \ \
@@011.1 FULL TEMPL
SUCCEEDED \
@@012 FULL TEMPL
LAST STATUS WAS ON \
CONNECTS SINCE CONNECTS SINCE
PORT/NODE LAST ENTRY STARTED
@@013 FULL TEMPL
\> / \> \>>>>>> \>>>>>>
@@014 FULL TEMPL
MESSAGE: \
@@100.1 FULL TEMPL
CI20 \
@@100.2 FULL TEMPL
CI20 Forced \ \
@@100.3 FULL TEMPL
NIA20 \
@@100.4 FULL TEMPL
NIA20 Forced \ \
@@101.1 FULL TEMPL
CI20 INFORMATION
CSR REG \00000,,000000 \
UCODE VERSION \>>>>>>>>>>>
UCODE \
CRAM ADDRESS \000/ \0000 \0000 \0000 \0000
@@101.2 FULL TEMPL
CI20 INFORMATION
CSR REG \00000,,000000 \
UCODE VERSION \>>>>>>>>>>>
UCODE \
CRAM ADDRESS \000 \
@@101.3 FULL TEMPL
NIA20 INFORMATION
CSR REG \00000,,000000 \
UCODE VERSION \>>>>>>>>>>>
UCODE \
CRAM ADDRESS \000/ \0000 \0000 \0000 \0000
@@101.4 FULL TEMPL
NIA20 INFORMATION
CSR REG \00000,,000000 \
UCODE VERSION \>>>>>>>>>>>
UCODE \
CRAM ADDRESS \000 \
@@102 FULL TEMPL
CHANNEL INFORMATION
STATUS WORD 0 \00000,,000000
CW 1 \00000,,000000
STATUS WORD 1 \00000,,000000 \
STATUS WORD 2 \00000,,000000
@@110 FULL TEMPL
COMMON DATA
COMMAND REF #: \0000000 HOST COMMAND #: \
CI20 PORT #: \>>>>>
NODE #: \>>>>>
SEQUENCE #: \>>>>>
FORMAT: \0 \
FLAGS: \0 \
EVENT: \000 \
CNTLR DEVICE #: \000\0000000
CNTLR CLASS: \0 \
CNTLR MODEL: \0 \
CNTLR SOFTWARE VER: \0
CNTLR HARDWARE VER: \0
@@112 FULL TEMPL
HOST MEMORY ERROR DATA
HOST MEM ADDR: \00000,,000000
@@103 FULL TEMPL
KLIPA Channel: \<
Reason for Counter gathers: \
CI node: \
Individual Counters:
PATH A ACK: \
PATH A NAK: \
PATH A NO RESP: \
PATH B ACK: \
PATH B NAK: \
PATH B NO RESP: \
DATAGRAMS DISCARDED: \
PACKETS TRANSMITTED: \
PACKETS RECEIVED: \
CRC ERRORS ON PACKETS: \
MOVER PARITY ERRORS: \
CBUS PARITY ERRORS: \
REGISTER PLIPE ERRORS: \
DATA PLIPE ERRORS: \
CHANNEL ERRORS: \
EBUS PARITY ERRORS: \
SPURIOUS CHANNEL ERRORS: \
CBUS AVAILABLE TIMEOUTS: \
SPURIOUS RECEIVE ATTENTIONS: \
SPURIOUS TRANSMIT ATTENTIONS: \
TRANSMIT BUFFER PAR ERRORS: \
TRANSMIT TIMEOUTS: \
@@113 FULL TEMPL
UNIT IDENTIFICATION DATA
UNIT NUMBER: \>>>>>
MULTI-UNIT CODE: \000
UNIT DEVICE #: \000\0000000
UNIT CLASS: \0 \
UNIT MODEL: \0 \
UNIT SOFTWARE VER: \0
UNIT HARDWARE VER: \0
VOLUME S/N: \0000000
@@114 FULL TEMPL
DISK TRANSFER DATA
LEVEL: \>>>
RETRY: \>>>
HEADER: \0000000 \
BLOCK AT ERROR WAS \
@@115 FULL TEMPL
SDI DATA
HEADER: \0000000 \
BLOCK AT ERROR WAS \
CONTROLLER DATA
REQUEST BYTE: \0 \
MODE BYTE: \0 \
ERROR BYTE: \0 \
CONTROLLER BYTE: \0
RETRY COUNT / FAILURE CODE: \0
@@116 FULL TEMPL
UNKNOWN DEVICE DATA
GET STATUS BYTES 11-8: \0000000
15-12: \0000000
@@116.1 FULL TEMPL
RA80/81 DEVICE DATA
LAST POSITION COMMAND: \0
SDI ERROR STATUS: \0 \
LAST SEEK CYLINDER: \0\0
HEAD NUMBER: \>>
MICROPROCESSOR LEDS: \0 \
FRONT PANEL FAULT CODE: \0 \
@@116.4 FULL TEMPL
RA60 DEVICE DATA
PREVIOUS CYLINDER: \000
PREVIOUS HEAD NUMBER: \>>
CURRENT CYLINDER: \000
CURRENT HEAD NUMBER: \>>
ERROR CODE: \0
@@117 FULL TEMPL
SMALL DISK DATA
CYLINDER: \>>>>>
@@120 FULL TEMPL
BYTES \-\ \00 \00 \00 \00 (\0)
@@120.7 FULL TEMPL
UNDEFINED DATA IN 8 BIT OCTAL BYTES
(UNUSED RIGHT 4 BITS IN 36-BIT WORD)
@@121 FULL TEMPL
MSCP STATUS (HEX): \00000000
@@122.7 FULL TEMPL
UNTRANSLATED DATA IN 8 BIT OCTAL BYTES
(UNUSED RIGHT 4 BITS IN 36-BIT WORD)
@@123.7 FULL TEMPL
EXTRANEOUS DATA IN 8 BIT OCTAL BYTES
(UNUSED RIGHT 4 BITS IN 36-BIT WORD)
@@200 FULL TEMPL
COMMON DATA
COMMAND REF #: \0000000 HOST COMMAND #: \
CI20 PORT #: \>>>>>
NODE #: \>>>>>
MEDIA ID: \00000,,000000 \
BLOCKS READ: \>>>>>>>>>>
BLOCKS WRITTEN: \>>>>>>>>>>
POSITION AT ERR 1: \>>>>>>>>>>
POSITION AT ERR 2: \>>>>>>>>>>
UNIT NUMBER: \>>>>>
ENDCODE: \0 \
FLAGS: \0 \
STATUS: \000 \
@@201 FULL TEMPL
READ OR WRITE COMMAND DATA
BYTE COUNT: \>>>>>>>>>>
FIRST BAD BLOCK: \>>>>>>>>>>
@@
Template blocks for Short style RFB blocks
@@010 SHORT TEMPL
DIAGNOSTIC \ V\, RUN BY PPN: \
@@011 SHORT TEMPL
FAILED TEST \ \
@@011.1 SHORT TEMPL
SUCCEEDED \
@@012 SHORT TEMPL
LAST STATUS WAS ON \
@@014 SHORT TEMPL
MESSAGE: \
@@100.1 SHORT TEMPL
CI20 \
@@100.2 SHORT TEMPL
CI20 Forced \ \
@@100.3 SHORT TEMPL
NIA20 \
@@100.4 SHORT TEMPL
NIA20 Forced \ \
@@101.1 SHORT TEMPL
CSR: \00000,,000000 CRAM ADDRESS: \000=\0000 \0000 \0000 \0000
UCODE \ \@
@@101.2 SHORT TEMPL
CSR: \00000,,000000 CRAM ADDRESS: \000
UCODE \ \@
@@101.3 SHORT TEMPL
CSR: \00000,,000000 CRAM ADDRESS: \000=\0000 \0000 \0000 \0000
UCODE \ \@
@@101.4 SHORT TEMPL
CSR: \00000,,000000 CRAM ADDRESS: \000
UCODE \ \@
@@102 SHORT TEMPL
PORT ERROR WORD: \000000,,000000
@@103 SHORT TEMPL
Counters on KLIPA channel # \< reason:\
@@110 SHORT TEMPL
HSC50 Error Message Node \ \
@@113 SHORT TEMPL
on \ #\ S/N \ \@
@@114 SHORT TEMPL
at \ \ \@
@@115 SHORT TEMPL
SDI Error - \ - \@
@@116 SHORT TEMPL
@@116.1 SHORT TEMPL
\ - \ - \
@@116.4 SHORT TEMPL
ERROR CODE: \
@@120.7 SHORT TEMPL
@@121 SHORT TEMPL
MSCP ERROR - MSCP STATUS (HEX)=\00000000
@@122.7 SHORT TEMPL
@@123.7 SHORT TEMPL
@@200 SHORT TEMPL
HSC50 End Message Node \ \: Unit \ \ \@
@@
The following messages are for DECNET Phase IV "Event
Logging Message" translation.
@@SHORT UNKNOWN FUNCTION CODE
DECNET Function Code ## -- ## bytes (No translation)
@@UNKNOWN FUNCTION CODE
No translation available for Function Code ##
Dump of ## data bytes in octal & decimal:
octal decimal
@@REMAINING BYTE DUMP
%%%% %%%%
@@SHORT DECNET TEXT
\\@
@@DECNET TEXT
\\@
@@
***** End of DECNET Phase IV messages! *****
@@PACKET SUMMARY
SPEAR Version ##. Retrieval from ##
Report generated ##
As directed by ##
Report sent to ##
@@PACKET WARNING
*** Warning (TOPS-10 only) ***
The original event file (from which the packet file was derived) must
exist in the original directory. Otherwise, the RETRIEVE output will be
incorrect.
@@OVERALL SUMMARY
SPEAR Version ##. Retrieval from ##
Report generated ##
As directed by ##
Selected window: ## to ##.
Selected records are ##
Selection type is ##
Report sent to ##
@@SHORT DATE
SEQ TIME \
@@SHORT HEAD
\ \ \@
@@FULL HEAD
***********************************************
##
LOGGED ON ## MONITOR UPTIME WAS ##
DETECTED ON SYSTEM # ##
RECORD SEQUENCE NUMBER: ##
***********************************************
@@SHORT 114
STATS DRIVE: ##, VOLID: ##, REASON: ##.
@@COMMON 114
Volume ID: ## Reason recorded: ##
Channel info(##): ## # ## on PI level ##
Device info(##): ##, ## ## PIA: ##
READS WRITES ##
TOTAL : %%%%%%%%%% %%%%%%%%%% %%%%%%%%%%
@@TAPE 114
NRZI : %%%%%%%%%% %%%%%%%%%%
PE : %%%%%%%%%% %%%%%%%%%%
GCR : %%%%%%%%%% %%%%%%%%%%
@@01_00
Extended sense data not updated
@@01_01
Extended sense data updated and contains something of interest
@@03_01
Command was issued with tape at BOT
@@03_02
Saw BOT indicator after tape motion started
@@03_03
ARA ID detected
@@11_01
TU is on-line but not ready (Possible when TU is manually rewound
or loading)
@@11_02
Fatal error has occurred and this command cannot be performed until
error status has been presented and a TM CLEAR received
@@11_03
Access to TU is allowed but TU is either rewinding or doing a DSE
from another MASSBUS or keypad command
@@15_01
No record found within 25 ft(7.6 m) of tape
@@15_02
ID Burst neither PE or GCR
@@15_03
ARA ID not found
@@15_04
No GAP found after ID Burst (PE) or ARA ID Burst (GCR)
@@20_00
Extended sense data not updated
@@20_01
Extended sense data updated and contains something of interest
@@21_00
Extended sense data not updated
@@21_01
Extended sense data updated and contains something of interest
@@22_01
CRC error, ACRC error, pointer mismatch, uncorrectable or two track
error set in ECCSTA register (This code generated by write GCR
operations)
@@22_02
CRC error, ACRC error, or uncorrectable set in ECCSTA register
(This code generated by read GCR operations)
@@22_03
Uncorrectable error set in ECCSTA register (This code generated
by read PE operations)
@@22_04
AMTIE, pointer mismatch, uncorrectable, two track error or single
track error set in ECCSTA register (This code generated by write PE
operations)
@@22_05
At least one bit set in ECCSTA register
@@22_06
At least one Write Fail bit set in RPFAIL and RPATH registers
(This code generated by write PE operations)
@@22_07
More than one Write Fail bit set in RPFAIL and RPATH registers
(This code generated by write GCR operations)
@@22_10
RSTAT contains bad code
@@22_11
CRC characters from WMC and RMC do not match (This code generated
by write PE operations)
@@22_12
MASSBUS data bus parity error
@@22_13
Record length incorrect during retry opposite attempt: invalid data
has been transferred
@@30_01
Illegal command code
@@30_02
Data transfer command issued while non-data transfer command in
progress on same tape unit
@@30_03
WMC error; check Encode register for reason. May be Illegal Format
or Skip Count codes
@@30_04
RUN not received`from MASSBUS controller
@@30_05
Command read from RMC register RCMLP did!not match command loaded
into RCMD register (This code generated in selected function
routine)
@@30_06
ECC ROM parity error
@@30_07
XMC ROM parity error
@@30_10
Command read from RMC register RCMLP did not match command loaded
into RCMD register (This code glnerated when Verify ID Burst
command loaded during write of BOT area)
@@30_11
Command read from RMC register RCMLP did not match command loaded
into RCMD register (This code generated when Verify ARA Burst
command loaded during write of BOT area)
@@30_12
Command read from RMC register RCMDP did not match command loaded
into RCMD register (This code generated when Verify ARA ID command
loaded during write of BOT area)
@@30_13
Command read from RMC register RCMLP did not match command loaded
into RCMD register (This code generated when Verify Gap command
loaded during write of BOT area)
@@30_14
Command read from RMC register RCMLP did not match command loaded
into RCMD register (This code generated when Read ID Burst command
loaded during read of BOT area)
@@30_15
Command read from RMC register RCMLP did not match command loaded
into RCMD register (This code generated when Verify ARA ID command
loaded during read of BOT area)
@@30_16
Command read from RMC register RCMLP did not match command loaded
into RCMD register (This code generated when Verify Gap command
loaded during read of BOT area)
@@30_17
Command read from RMC register RCMLP did not match command loaded
into RCMD register (This code generated when Find Gap command
loaded during Erase Gap routine)
@@30_20
WMC LEFT failed to set in Extended Sense routine
@@30_21
XL PE set in INTSTA register
@@30_22
XMC DONE did not set
@@30_23
WMC ROM PE or RD PE set in WMCERR register
@@31_01
TU Status parity error
@@31_02
TU Command parity error
@@31_03
Rewinding tape went off-line
@@31_04
Tape went not ready during DSE
@@31_05
TU CMD status changed during DSE
@@31_06
TU velocity never came up to speed
@@31_07
TU velocity changed after up to speed and writing started
@@31_10
TU CMD did not load correctly to start tape motion in selected
function routine
@@31_11
TU CMD did not load correctly to set drive density
@@31_12
TU CMD did not load correctly to set drive density
@@31_13
TU CMD did not load correctly to set drive density
@@31_14
Failed to write density ID Burst correctly
@@31_15
Failed to write ARA Burst correctly
@@31_16
Failed to write ARA ID correctly
@@31_17
ARA error bit set in MTA Status B register
@@31_20
unknown
@@31_21
Could not find a gap after the ID code was written correctly
@@31_22
TU CMD did not load correctly to start tape motion to read ID Burst
@@31_23
Time-out looking for BOT after detecting ARA ID Burst
@@31_24
Failed to write Tape Mark correctly
@@31_25
Tape never came up to speed while trying to reposition for retry of
writing Tape Mark
@@31_26
TU CMD did not load correctly to start tape motion in Erase Gap
routine
@@31_27
Could not detect a gap in Erase Gap routine
@@31_30
Could not detect a gap after writing record
@@31_31
Read path terminated before entire record was written
@@31_32
Could not find a gap after writing record and read path terminated
early
@@31_33
TU CMD did not load correctly to backup for retry of Write Tape Mark
@@31_34
TU Velocity changed after up to speed while trying to reposition
for retry of writing Tape Mark
@@31_35
TU CMD did not load correctly to backup to retry a read of BOT ID
@@31_36
Time-out looking for BOT after failing to write BOT ID
@@31_37
TU velocity changed while writing PE gap before starting to write
record
@@31_40
TU CMD did not load correctly to set PE tape density at start of
write BOT ID Burst
@@31_41
TU CMD did not load correctly to set GCR tape density after writing
Density ID
@@31_42
TU CMD did not load correctly to set PE tape density at start of
read from BOT
@@31_43
TU CMD did not load correctly to set GCR tape density after reading
a GCR Density ID Burst
@@32_00
RST0 interrupt occurred with TM RDY still set
@@32_01
Power failed to interrupt
@@32_02
Interrupt for unknown readon on channel 5.5
@@32_03
Interrupt for unknown readon on channel 6.5
@@32_04
Interrupt for unknown readon on channel 7
@@32_05
05 Interrupt for unknown readon on channel 7.5
@@32_06
CAS contention retry count expired
@@32_07
CAS Contention error not retryable
@@32_10
Queue error; could not find queue entry
@@32_11
Queue entry already full
@@32_12
8085 ROM parity error
@@32_13
In-line test 0; WMC self test failed = M8959-M8957
@@32_14
In-line test 1; XMC ROM parity error M8958-M8959-M8960
@@32_15
In-line test 2; RPM self test failed M8953-M8960
@@32_16
In-line test 3; RPM1 channel 0 self test failure M8950 (slot AB12)
@@32_!7
In-line ueSt 4; RPM1 channel 1 self test failure M8950 (slot AB13)
@@32_20
In-line test 5; RPM1 channel 2 self test failure M8950 (slot AB14)
@@32_21
In-line test 6; RPM1 channel 3 self test failure M8950 (slot AB15)
@@32_22
In-line test 7; RPM1 channel 4 self test failure M8950 (slot AB16)
@@32_23
In-line test 10; RPM1 channel 5 self test failure M8950 (slot CD13)
@@32_24
In-line test 11; RPM1 channel 6 self test failure M8950 (slot CD14)
@@32_25
In-line test 12; RPM1 channel 7 self test failure M8950 (slot CD15)
@@32_26
In-line test 13; RPM1 channel P self test failure M8950 (slot CD16)
@@32_27
In-line test 14; RPM1 error correction self test M8950-M8951-M8953
@@32_30
In-line test 15; 40000-40777 RAM memory failure M8960
@@32_31
In-line test 16; 41000-41777 RAM memory failure M8960
@@32_32
In-line test 17; 42000-42777 RAM memory failure M8960
@@32_33
In-line test 20; 43000-43777 RAM memory failure M8960
@@32_34
In-line test 21; 44000-44777 RAM memory failure M8960
@@32_35
In-line test 22; 45000-45777 RAM memory failure M8960
@@32_36
In-line test 23; 46000-46777 RAM memory failure M8960
@@32_37
In-line test 24; 47000-47777 RAM memory failure M8960
@@32_40
In-line test 25; loop write to read at TU port 0 - GCR
@@32_41
In-line test 26; loop write to read at TU port 0 - PE
@@32_42
In-line test 27; loop write to read at TU port 1 - GCR
@@32_43
In-line test 30; loop write to read at TU port 1 - PE
@@32_44
In-line test 31; loop write to read at TU port 2 - GCR
@@32_45
In-line test 32; loop write to read at TU port 2 - PE
@@32_46
In-line test 33; loop write to read at TU port 3 - GCR
@@32_47
In-line test 34; loop write to read at TU port 3 - PE
@@32_50
In-line test 35; loop write to read at MTA 0 - GCR
@@32_51
In-line test 36; loop write to read at MTA 0 - PE
@@32_52
In-line test 37; loop write to read at MTA 1 - GCR
@@32_53
In-line test 40; loop write to read at MTA 1 - PE
@@32_54
In-line test 41; loop write to read at MTA 2 - GCR
@@32_55
In-line test 42; loop write to read at MTA 2 - PE
@@32_56
In-line test 43; loop write to read at MTA 3 - GCR
@@32_57
In-line test 44; loop write to read at MTA 3 - PE
@@34_01
Control bus parity error
@@34_02
Illegal register referenced
@@77_01
Keypad entry error
@@77_02
TM78 not off-line
@@77_03
Illegal instruction code
@@77_04
Microdiagnostic start or continue command issued
@@77_05
Microdiagnostic loop on error command issued
@@UNKNOWN TU78
UNEXPECTED combination -- interrupt code: ##
failure code: ##
@@