Trailing-Edge
-
PDP-10 Archives
-
AP-D543V_SB
-
mk514d.ct
There are 2 other files named mk514d.ct in the archive. Click here to see a list.
;%1(74) VERSION OF MK514D 20 OCT 78 /MS
;THIS MK514D.CT FILE IS MASSAGED BY TECO TO HAVE ALL # # # 'S TURN
; INTO THE CURRENT VERSION NUMBER OF THE MONITOR AT WHICH TIME IT
; BECOMES MK514D.CTL, THE CONTROL FILE WHICH LOADS A MONITOR FOR
; DECSYSTEM-10 #514/546 (OUR IN-HOUSE KI10 DUAL DEVELOPMENT SYSTEM).
;THIS IS A "STANDARD" MONITOR, I.E., WITHOUT VIRTUAL MEMORY.
;
G514D:: ;
.CHKPNT G514D
.SET WATCH ALL
.IF (ERROR) ;O.K.
;
;AVOID USING VIRTUAL MEMORY
.SET PHYSICAL 256
.IF (ERROR) ;OK, WE MUST BE ON A KA10
;
;THIS IS THE SYSTEM #514/546 HARDWARE CONFIGURATION
;
.RUN DSK:MONGEN
*
*HDW
*HDW14D
*1077
* R7### SYS #514/546
*514 ;CPU0 SERIAL NUMBER
*2 ;DK10 CLOCKS ON CPU0
*546 ;CPU1 SERIAL NUMBER
*1 ;DK10 CLOCKS ON CPU1
*Y ;EXCLUDE MONITOR OVERHEAD?
*Y ;HIGH PRECISION TIME ACCOUNTING?
*4 ;# OF DATA CHANNELS
*DF10C ;TYPE CHANNEL
*0 ;RC10 ON CHANNEL 0
*0 ;RH10 FOR RS04
*1 ;RH10 FOR RP04
*8 ;RPA'S
*0 ;RP10
*0 ;# OF TM10BS
*0 ;# OF TC10CS
*0 ;RH10'S FOR TM02'S
*DF10C ;TYPE CHANNEL
*0 ;RC10 ON CHANNEL 1
*0 ;RH10 FOR RS04
*1 ;RH10 FOR RP04
*8 ;RPB'S
*1 ;RP10
*2 ;DPA'S
*0 ;# OF TM10BS
*0 ;# OF TC10CS
*0 ;RH10'S FOR TM02'S
*DF10C ;TYPE CHANNEL
*0 ;RC10 ON CHANNEL 2
*0 ;RH10 FOR RS04
*0 ;RH10 FOR RP04
*0 ;RP10
*1 ;# OF TM10BS
*2 ;MTAS
*0 ;# OF TC10CS
*0 ;RH10'S FOR TM02S
*DX10 ;TYPE CHANNEL
*1 ;# OF TX01S ON CHANNEL 3
*7 ;MTBS (TU70)
*1 ;# OF TM10AS
*2 ;MTCS
* ;MTAS ON 7 TRACK
*4 ;MTBS ON 7 TRACK
*
* ;(MTCS)END MAGTAPE DEFINITION
*
*
* ;END MAGTAPE DENSITY
*100 ;JOBS
* ;MAX PAGES CORE/USER
*384 ;TOTAL CORE
*60 ;TICKS/SEC
*3 ;REAL TIME DEVICES
*0 ;GUARANTEED CORE FOR NON-LOCKED JOBS
*3 ;HPQ'S
*Y ;CCL
*Y ;METER
*Y ;SYSCHK
*Y ;MSGSER
*Y ;PSISER
*Y ;IPCSER
*Y ;ENQ/DEQ
*0 ;CDR'S
*N ;CDP
*N ;DISPLAY
*2 ;TD10'S (DECTAPE CONTROLLERS)
*4 ;DTA'S
*2 ;DTB'S
*2 ;LPT'S
*Y ;LPT0 LOWER CASE
*N ;LPT1 UPPER CASE ONLY
*1 ;PLT'S
*Y ;PTP
*Y ;PTR
*55 ;PTY'S
*N ;DC44
*0 ;# OF DA28'S
*0 ;# OF DC78'S
* ;DECIMAL VALUE DEFINITIONS
*A1077S,0
*PRVFIL,055
*LIMLVL,5
*DEFDEB,320000000000
*RTCH1,1
*MBFN,5 ;NUMBER OF MONITOR BUFFERS
*M.DFNB,6 ;DEFAULT NUMBER OF USER BUFFERS
*MTDLTP,1 ;STANDARD MAGTAPE LABELS ARE ASCII
* ;END OCTAL VALUE DEFINITIONS
* ;SIXBIT VALUE DEFINITIONS
* ;DEV,PI
* ;DEV,PI,#
* ;DEV,PI,AC
;
;THIS IS THE SYSTEM #514/546 TELETYPE CONFIGURATION
;
.RUN DSK:MONGEN
*
*TTY
*TTY14D
*1077 ;TYPE PROCESSOR
*1 ;DC10'S
*0 ;DC68'S
*1 ;DC76'S
*2 ;DC10B
*0 ;DC10E
*1 ;DL10 PORT
*80 ;DC76 LINES
*CTY ;OPR
* ;DATA SETS
*2-4 ;TABS
*10-23
*30-46
*CTY
*CTY1
*
;ONLY THE CTY, TTY0 ("PLEASE") AND VT06 MAY LOG-IN AS [1,2]
*2-330 ;REMOTE
*
* ;LOCAL COPY
* ;HALF DUPLEX
* ;SLAVES
* ;FORM FEED
;INITIA
*CTY
*CTY1
*0-7
*
*1,1 ;FILLER FOR VT06
*
*3 ;2741 INTERFACE LINE #
*
;
;THIS IS THE SYSTEM #514/546 NETWORK CONFIGURATION
;
.RUN DSK:MONGEN
*
*NET
*NET14D
*Y ;NETWORKS SUPPORTED
*16 ;NODES
*3 ;DC75'S OR DN87'S
*0 ;PORT #-DC75
*4 ;PORT #-DN75
*5 ;PORT #-DN87
*0 ;NUMBER OF DN87S'S
*14 ;CENTRAL SITE NODE NUMBER
;CENTRAL SITE NAME
*KI514
*64 ;REMOTE TTY'S
*2 ;REMOTE CDR'S
*2 ;REMOTE LPT'S
*0 ;REMOTE PTR'S
*0 ;REMOTE PTP'S
*0 ;REMOTE MTA'S
*16 ;REMOTE PROCESSES
*N ;REMOTE DATA ENTRY
*100 ;CONNECTS (TOTAL # OF DEVICES THAT CAN BE CONNECTED)
;
;END OF SYSTEM #514/546 MONGEN DIALOGUES
;
;AT THIS POINT MK514D.CTL EITHER CONTINUES PROCESSING ON ITS OWN OR RETURNS
; CONTROL TO WHATEVER OTHER FILE CALLED IT AS A SUBROUTINE....
.RUN DEC:TECO
*ERMK514D.KLG
.IF (ERROR) .GOTO A514D ;CONTINUE PROCESSING IF MK514D.KLG FILE NOT PRESENT.
;IF MK514D.KLG FILE IS PRESENT IT CONTAINS A POINTER BACK TO THE FILE WHICH CALLED
; THIS FILE AS A SUBROUTINE, SO USE IT TO RETURN CONTROL AS FOLLOWS:
.SUBMIT MK514D.KLG/UNIQ:0/AFTER:+0:01
.IF (ERROR) .PLEASE CANNOT EXIT FROM MK514D.CTL VIA MK514D.KLG
;KILL THIS JOB IF IT WAS BEING USED AS A SUBROUTINE
.KJOB/F
;
;CONTINUE PROCESSING IF MK514D.CTL WAS CALLED AS A MAIN JOB INSTEAD OF A SUBROUTINE.
;
A514D:: ;
.CHKPNT A514D
.SET WATCH ALL
.IF (ERROR) ;OKAY
.PLEASE CHKPNT A514D
;
;AVOID USING VIRTUAL MEMORY
.SET PHYSICAL 256
.IF (ERROR) ;OK, WE MUST BE ON A KA10
;
;NOTE: SINCE THIS MONITOR IS FOR OUR "BASE" KI10 SYSTEM, ITS COMMON,
; COMDEV, COMNET, AND COMMOD WERE NORMALLY ASSEMBLED BY MONMKI.
;HOWEVER, PROVIDE FOR THE POSSIBILITY THAT MK514D IS BEING RUN WITHOUT HAVING
; RUN MONMKI. ASSEMBLE COMMON ET AL ONLY IF .RLI FILES DO NOT EXIST......
.ASSIGN DEC SYS ;FORCE USE OF FIELD IMAGE COMPIL, MACRO
.RUN DEC:TECO
*ERCOMMON.RLI
.IF (NOERROR) .GOTO A1
.ERROR %
.R MACRO
*F14D/U_FKI
*S14D/U_S
*COMMON.RLI_HDW14D,TTY14D,NET14D,COMMON
.IF (ERROR) .PLEASE 1077 COMMON ASSEMBLY ERROR--MK514D PROCEEDING
A1:: ;
.RUN DEC:TECO
*ERCOMDEV.RLI
.IF (NOERROR) .GOTO A2
.R MACRO
*F14D/U_FKI
*S14D/U_S
*COMDEV.RLI_HDW14D,TTY14D,NET14D,COMDEV
.IF (ERROR) .PLEASE 1077 COMDEV ASSEMBLY ERROR--MK514D PROCEEDING
A2:: ;
.RUN DEC:TECO
*ERCOMNET.RLI
.IF (NOERROR) .GOTO A3
.R MACRO
*F14D/U_FKI
*S14D/U_S
*NP14D/U_NETPRM
*COMNET.RLI_HDW14D,TTY14D,NET14D,COMNET
.IF (ERROR) .PLEASE 1077 COMNET ASSEMBLY ERROR--MK514D PROCEEDING
A3:: ;
.RUN DEC:TECO
*ERCOMMOD.RLI
.IF (NOERROR) .GOTO A4
.R MACRO
*F14D/U_FKI
*S14D/U_S
*COMMOD.RLI_HDW14D,COMMOD
.IF (ERROR) .PLEASE 1077 COMMOD ASSEMBLY ERROR--MK514D PROCEEDING
A4:: ;
.RUN DEC:TECO
*ERTSKSER.RLI
.IF (NOERROR) .GOTO A5
.R MACRO
*F14D/U_FKI
*S14D/U_S
*TSKSER.RLI_TSKSER
.IF (ERROR) .PLEASE 1077 TSKSER ASSEMBLY ERROR--MK514D PROCEEDING
A5:: ;
.ERROR
.DEASSIGN SYS
;
K514D:: ;
.CHKPNT K514D
.SET WATCH ALL
.IF (ERROR) ;O.K.
; NEXT LOAD A MONITOR FOR OUR IN-HOUSE DUAL CPU (DECsystem10 1077) SYSTEM
;
L514D:: ;
.CHKPNT L514D
.SET WATCH ALL
.IF (ERROR) ;OKAY
.PLEASE CHKPNT L514D--BEGINNING 1077 LOAD
;
;AVOID USING VIRTUAL MEMORY
.SET PHYSICAL 256
.IF (ERROR) ;OK, WE MUST BE ON A KA10
;
.RUN DEC:PIP
*R7###.MAP<157>_TTY:
=^Z
.IF (ERROR) ; NICE TRY
;USE FIELD IMAGE VERSION OF LINK-10
.ASSIGN DEC SYS
.R LINK
.IF (ERROR) .PLEASE LINK-10 IS REQUIRED TO LOAD R7### - BETTER ABORT
*/NOINITIAL /HASH:6000 R7###/SAVE ,R7###/MAP /CONTENT:NONE = /LOCALS /MAXCOR:60K -
*COMMON.RLI,COMDEV.RLI,COMNET.RLI,COMMOD.RLI,TSKSER.RLI,TOPI10/SEARCH /PATCHSIZE:200 /GO
.IF (ERROR) .PLEASE ERROR LOADING MONITOR R7### USING LINK10--PROCEEDING
.DEASSIGN SYS
;
.QUEUE R7###.MAP/PRIORITY:47/DISPOSE:PRESERVE
.IF (ERROR) .PLEASE COULDN'T PRINT R7###.MAP
;
;NOW PRODUCE AN .EXE FILE INSTEAD OF .SAV OR .HGH/.LOW
N514D::
.CHKPNT N514D
.SET WATCH ALL
.IF (ERROR) ;OKAY
.SET PHYSICAL 256
.IF (ERROR) ;OKAY, WE MUST BE ON A KA10
.GET R7###
.IF (ERROR) .GOTO Q514D ;NOT ENOUGH CORE TO .GET MONITOR
.NSAV R7###
.IF (NOERROR) .GOTO F514D ;R7###.EXE CREATED CORRECTLY
.PLEASE NSAV R7### LOST -- ABORTING
.GOTO E514D
Q514D::
.RUN DEC:FILEX
*R7###.EXE=R7###.HGH
.IF (NOERROR) .GOTO F514D
.PLEASE FILEX COULDN'T MAKE R7###.EXE -- ABORTING
.GOTO E514D
;
; CREATE FILDDT FOR 1077 DUAL CPU MONITOR
;
F514D:: ;
.CHKPNT F514D
.SET WATCH ALL
.IF (ERROR) ; OKAY
.PLEASE CHKPNT F514D--FILDDT
;
.RUN DSK:FILDDT
*R7###.EXE/S
.NSAV DSK:FR7###
.DELETE F14D.*,S14D.*,NP14D.*,R7###.XPN,R7###.HGH,R7###.LOW
.IF (ERROR) ; NICE TRY
;
;FINALLY, COPY RESULTS BACK TO THE BLACK PACKS
;
C514D:: ;
.CHKPNT C514D
.SET WATCH ALL
.IF (ERROR) ;O.K.
.PLEASE CHKPNT C514D--READY TO COPY TO BLKA: ?
;THIS WAITS FOR OPERATOR TO CONTINUE......
.MOUNT BLKA:
.IF (ERROR) .PLEASE CAN'T MOUNT BLKA:--BETTER ABORT
.RUN DEC:PIP
*BLKA:[7,5111]<100>/X/B_R7###.EXE,R7###.MAP
.IF (ERROR) .PLEASE TROUBLE COPYING ONTO BLKA:
.GOTO X514D
%ERR:: .GOTO E514D
%CERR:: .GOTO E514D
E514D:: .PLEASE ERROR IN MK514D--EXAMINE .LOG FILE
.QUEUE MK514D.LOG/DISPOSE:PRESERVE
.GOTO X514D
X514D:: .PLEASE MK514D FINISHED
%FIN:: ;
.KJOB/F
;[END OF MK514D.CT(L)]