Trailing-Edge
-
PDP-10 Archives
-
BB-4172H-BM
-
4-1-documentation/format.tco
There are 7 other files named format.tco in the archive. Click here to see a list.
TOPS20 Change Order Number 5.1.1095
Written by: HAUDEL 12-Oct-82 14:15:16
Edit checked: NO Document: NO
TCO Tested: NO Maintenance Release: NO
Hardware-related: YES
Program: FORMAT
Related TCO's:
Related SPR's:
Problem: The VERIFY command always finds hard disk errors with
large cylinder numbers
Diagnosis: VERIFY uses the DSKOP% jsys which will not access the
last few physical cylinders on a disk. For instance, there are
411 cylinders on an RP04, but TOPS-20 only uses the first 400.
Solution: Change the VERIFY code in FORMAT to only verify the
cylinders that TOPS-20 can use.
[End of TCO 5.1.1095]