SORT.HLP
The general command format is:
OUTPUT=INPUT/SWITCH:ARGUMENT,...
The switches are:
AFTER Write ASCII record after <cr-lf>
ALIGN Word align all output ASCII records (saves time)
ALPHANUMERIC Data type
ASCII Data mode of file
BEFORE Write ASCII record before <cr-lf>
BINARY Data mode of file
BLOCK:n n = Blocking factor
CHECK When merging check the sequence of the input records
COMP Computational data type
COMP1 Floating point data type
COMP3 Packed (4 bits) decimal data type
COMPUTATIONAL Data type
CORE Low segment core size
EBCDIC Data type
COLLATE:a a is one of the following:
ASCII collating sequence
EBCDIC collating sequence
FILE:file-spec
LITERAL:/collating-sequence/ first char after colon is delimeter
ADDRESS:n Octal address
ERROR:n Octal address
FATAL:n Octal address
FIXED Fixed length records
FORMAT:f Data type is FORTRAN floating point ASCII
f is FORTRAN format descriptor
FORTRAN Data file produced by FORTRAN (ASCII or BINARY)
INDUSTRY Industry compatible (8 bit) mode
KEY:f:s:o f = first byte, s = size
o = ASCENDING or DESCENDING
LABEL:a a is one of the following:
STANDARD, NONSTANDARD, OMITTED, DEC, ANSI or IBM
LEAVES:n n = number of records to keep in main memory
MAXTEMP:n n = max. number of temporary files to use
MERGE Merge the presorted input files
NOCRLF Read and write ASCII records with no <cr-lf>
NUMERIC Data type
PACKED Same as COMP3
POSITION:n Position to n'th file on multi-file tape
PRIORITY:n Disk priority (-3 to 3)
RANDOM FORTRAN binary data type
RECORD:s s = size in bytes
REWIND Rewind device before use
SEQUENTIAL FORTRAN binary data type
SIGNED Numeric field has operational sign
SIXBIT Data type
STANDARD Standard ASCII mode
SUPPRESS:a a is one of the following:
ALL, FATAL, INFORMATION, NONE, WARNING
TEMP Device is to be used for temporary files
UNLOAD Unload device after use
UNSIGNED Field does not have operational sign
VARIABLE Variable record size
The following switches are implemented by SCAN:
DENSITY of magtape
ESTIMATE block size of output file
HELP Type this file
PARITY of magtape
PHYSICAL Physical-only LOOKUPs and ENTERs
PROTECTION of output file
RUN other program to run
RUNCORE Size of program to run
RUNOFFSET 0 or 1 for normal or CCL mode start
VERSION Version number of output file
The following are recognized by SCAN but have no effect:
ABEFORE
ASINCE
BEFORE
ERNONE
ERPROTECTION
ERSUPERSEDE
LENGTH
MESSAGE
NOOPTION
OKNONE
OKPROTECTION
OKSUPERSEDE
OPTION
SINCE
STRS
[END OF SORT.HLP]