Trailing-Edge
-
PDP-10 Archives
-
BB-H138C-BM
-
5-documentation/dx20ld.tco
There are 9 other files named dx20ld.tco in the archive. Click here to see a list.
TOPS20 Change Order Number 4.1.1123
Written by: DBELL 26-Mar-80 13:42:18
Edit checked: NO Document: YES
TCO Tested: NO Maintenance Release: NO
Hardware-related: YES
Program: DX20LD
Related TCO's:
Related SPR's:
Problem:
The RP20 needs to have its DX20 loaded, and DX20LD only knows how to
load the TU7x style DX20.
Diagnosis:
No code existed.
Solution:
Change DX20LD to be able to load both kinds of DX20. Add the /R and /T
switches to specify which kind to load when necessary. Also default the
DX20 type based on the filename specified (RP20 microcode for DXMCE and
TU7x microcode for DXMCA).
[End of TCO 4.1.1123]
TOPS20 Change Order Number 5.1185
Written by: UHLER 31-Oct-80 07:36:37
Edit checked: NO Document: NO
TCO Tested: NO Maintenance Release: YES
Hardware-related: NO
Program: DX20LD
Related TCO's:
Related SPR's:
Problem: DX20LD sometimes can't find the microcode files if one specifies
a filespec that isn't the connected directory.
Diagnosis: GJ%OLD needs to be set in the GTJFN block to force it to look
beyond the first directory in a (logical) device spec.
Solution: Set GJ%OLD in the GTJFN
[End of TCO 5.1185]