Trailing-Edge
-
PDP-10 Archives
-
BB-H138D-BM
-
5-1-documentation/watch.tco
There are 14 other files named watch.tco in the archive. Click here to see a list.
TOPS20 Change Order Number 5.1450
Written by: MOSER 11-Aug-81 12:12:56
Edit checked: NO Document: NO
TCO Tested: NO Maintenance Release: NO
Hardware-related: NO
Program: WATCH
Related TCO's:
Related SPR's:
Problem: IF A USER TYPES GARBAGE TO THE QUESTION PRINT MONITOR STATISTICS?
HE CAN ONLY ANSWER Y OR N ON SUBSEQUENT TYPINS THE ANSWER "A" IS NO LONGER
ACCEPTED.
Diagnosis: AFTER CHECKING FOR "A" THE ROUTINE YESNOX IS CALLED AND IT WILL NOT
RETURN UNTIL IT SEES A "Y" OR "N".
Solution: DON'T CALL YESNOX HERE INSTEAD CHECK FOR "Y" OR "N" AND IF NEITHER
ASK AGAIN.
[End of TCO 5.1450]
TOPS20 Change Order Number 5.1527
Written by: PAETZOLD 22-Sep-81 17:27:11
Edit checked: NO Document: NO
TCO Tested: NO Maintenance Release: NO
Hardware-related: NO
Program: WATCH
Related TCO's: 5.1555
Related SPR's:
Problem:
Watch doesnt have enough jobs.
Diagnosis:
NJOBS os set for 80.
Solution:
Set it for 128.
[End of TCO 5.1527]
TOPS20 Change Order Number 5.1555
Written by: PAETZOLD 1-Oct-81 13:19:18
Edit checked: NO Document: NO
TCO Tested: NO Maintenance Release: NO
Hardware-related: NO
Program: WATCH
Related TCO's: 5.1527
Related SPR's:
Problem:
TCO 5.1527 set NJOBS to 80. The monitor snoop space does not have enough
room for this.
Diagnosis:
There is not room to increase the snoop space to the extent needed for MONMAX.
Solution:
Remove TCO 5.1527
[End of TCO 5.1555]