C FD7T1
C This program opens a remote file named DAP.TST and writes an
C ASCII record into it, closes the file, reopens the file and
C reads the record back and then closes the file again. NOTE:
C This program reads and writes the file DAP.TST from a
C directory called PS:<DIL-TEST>. If this directory does not
C exist, it must be created as a valid login directory.
C
C COPYRIGHT (C) DIGITAL EQUIPMENT CORPORATION 1982, 1983
C
C This software is furnished under a license and may be used and
C copied only in accordance with the terms of such license and with
C the inclusion of the above copyright notice. This software or any
C other copies thereof may not be provided or otherwise made available
C to any other person. No title to and ownership of the software is
C hereby transferred.
C
C The information in this software is subject to change without notice
C and should not be construed as a commitment by Digital Equipment
C Corporation.
C
C Digital assumes no responsibility for the use or reliability of its
C software on equipment which is not supplied by Digital.
C
C
C Facility: DIT-TEST
C
C Edit History:
C
C new_version (1, 0)
C
C Edit (%O'1', '15-Dec-82', 'Sandy Clemens')
C %( Add the DIT (Dap and Task-to-task) Installation Verification tests
C for the VAX and DECSYSTEM-20 to the library.
C Files: DITTHST.TXT (NEW), CD32T1.VAX-COB (NEW),
C CT32T1.VAX-COB (NEW), FD32T1.VAX-FOR (NEW),
C FT32T1.VAX-FOR (NEW), CD36T1.CBL (NEW), CT36T1.CBL (NEW),
C FD6T1.FOR (NEW), FD7T1.FOR (NEW), FT6T1.FOR (NEW),
C FT7T1.FOR (NEW) )%
C
C Edit (%O'2', '14-Jan-83', 'Sandy Clemens')
C %( Many edits to the Installation Verification system (ICS) files.
C Add SYS: to all the 10/20 programs in the COPY or INCLUDE
C statement for the interface files. Add SYS$LIBRARY to the VAX
C programs in the COPY or INCLUDE statement for the interface
C files. Add check for INFO or SUCCESS status return in all ICS
C programs. Remove node names from all DIT programs so that local
C node is used. Change directory used by 20 DAP programs to be
C PS:<DIL-TEST> with password DIL-TEST. Remove all directory
C specifications from VMS programs so they use the default
C connected directory. Add Lib$Match_Cond to VMS programs for
C status checking. Change some of the symbolic variable names for
C clarification. Change use of numeric parameter values to
C symbolic variable names. Get rid of use of "IMPLICIT INTEGER"
C in FORTRAN test programs. Add copyright notice to everything.
C
C Files: CD32T1.VAX-COB, CD36T1.CBL, CT32T1.VAX-COB, CT36T1.CBL,
C FD32T1.VAX-FOR, FD6T1.FOR, FD7T1.FOR, FT32T1.VAX-FOR, FT6T1.FOR,
C FT7T1.FOR, DITTHST.TXT )%
C
C Edit (%O'6', '25-Jan-83', 'Sandy Clemens')
C %( Add copyright and liability waiver to whatever needs it.
C FILES: CD32T1.VAX-COB, CD36T1.CBL, CT32T1.VAX-COB, CT36T1.CBL,
C FD32T1.VAX-FOR, FD6T1.FOR, FD7T1.FOR, FT32T1.VAX-FOR, FT6T1.FOR,
C FT7T1.FOR, SUB6D1.FOR, SUB6T1.FOR, SUB7D1.FOR, SUB7T1.FOR )%
C Use the DIL interface files
INCLUDE 'SYS:DITV7'
INCLUDE 'SYS:DILV7'
C File and directory description fields
INTEGER FNAME (8), USERID (8), PASSWD (8), ACCT (8), FNUMBR
C Sending and receiving data records
INTEGER DATA1 (20), DATA2 (20)
C DIL Status code
INTEGER STAT
C Record size and record unit size
INTEGER RSIZE, RUNTSZ
DATA FNAME /'PS:<D', 'IL-TE', 'ST>DA', 'P.TST', ' ',
1 ' ', ' ', ' '/
DATA USERID /'DIL-T','EST ', ' ', ' ',
1 ' ', ' ', ' ', ' '/
DATA PASSWD /' ', ' ', ' ', ' ', ' ',
1 ' ', ' ', ' '/
DATA ACCT /' ', ' ', ' ', ' ',
1 ' ', ' ', ' ', ' '/
C Program messages
200 FORMAT (' ROPEN status return: ', I12)
201 FORMAT (' RWRITE status return: ', I12)
202 FORMAT (' RCLOSE status return: ', I12)
203 FORMAT (' RREAD status return: ', I12)
700 FORMAT ('? Invalid status returned... ')
C Request the password
900 FORMAT (' Enter the password: ')
WRITE (5,900)
901 FORMAT (8A5)
ACCEPT 901, PASSWD
C Open file DAP.TST for output
RSIZE = 100
RUNTSZ = 0
STAT = ROPEN (FNUMBR, FNAME, USERID, PASSWD, ACCT, MWRITE,
1 TASCII, FSTM, AUNSPC, RSIZE, RUNTSZ)
WRITE (5,200) STAT
IF (STAT .EQ. NORMAL) GO TO 100
WRITE (5,700)
STOP
C Accept a record and write it to the file
101 FORMAT (' Enter data for the record: ')
100 WRITE (5,101)
102 FORMAT (20A5)
ACCEPT 102, DATA1
STAT = RWRITE (FNUMBR, RUNTSZ, RSIZE, DATA1)
WRITE (5,201) STAT
IF (STAT .EQ. NORMAL) GO TO 103
WRITE (5,700)
STOP
C Close the file
103 STAT = RCLOSE (FNUMBR, ONTHNG)
WRITE (5,202) STAT
IF (STAT .EQ. NORMAL) GO TO 104
WRITE (5,700)
STOP
C Open the file to read the record
104 STAT = ROPEN (FNUMBR, FNAME, USERID, PASSWD, ACCT, MREAD,
1 TASCII, FSTM, AUNSPC, RSIZE, RUNTSZ)
WRITE (5,200) STAT
IF (STAT .EQ. NORMAL) GO TO 105
WRITE (5,700)
STOP
C Read the record
105 STAT = RREAD (FNUMBR, RUNTSZ, RSIZE, DATA2)
WRITE (5,203) STAT
IF (STAT .EQ. NORMAL) GO TO 106
WRITE (5,700)
STOP
107 FORMAT (' The record read was: ')
106 WRITE (5,107)
110 FORMAT (' ', 20A5)
WRITE (5,110) DATA2
C Close the file
STAT = RCLOSE (FNUMBR, ONTHNG)
WRITE (5,202) STAT
IF (STAT .EQ. NORMAL) GO TO 108
WRITE (5,700)
STOP
109 FORMAT (' FD7T1 test successful.')
108 WRITE (5,109)
STOP