Trailing-Edge
-
PDP-10 Archives
-
BB-T573C-DD_1986
-
2,5/rmtcon.hlp
There are 10 other files named rmtcon.hlp in the archive. Click here to see a list.
!RMTCON.HLP RMTCON online help file
!
! Updated 20-Jun-85 by Gregory A. Scott
!
!Each RMTCON command has an entry in this file. The entries must be
!alphabetically ordered and must be preceeded with an "*" in column 1.
!The command must be spelled out with nothing else on the line.
!Additional entries may be added to this help file, but care must be
!taken to follow the above.
To see all the AVAILABLE COMMANDS, type "?" after the program PROMPT.
To see all the AVAILABLE COMMAND OPTIONS, type "?" after the COMMAND.
For help on a SPECIFIC command, type "HELP <command>" at the PROMPT.
For help on ALL commands, type "HELP *" after the program PROMPT.
To see this text again, type "HELP" after the program PROMPT.
*CONNECT
CONNECT PORT n
The port is the Ethernet channel on this CPU. The allowed ports are 0,1,2,3.
CONNECT NODE address
Connects to the console of the specified node address, a 12 digit hex
number. Hyphens may be used anywhere in the hex address. Any other
format will result in an error message & will have to be re-entered.
Note: To enter uODT after a CONNECTION has been made, type a
CONTROL-B, which sends a break.
To exit uODT and proceed, type P<cr>.
*DISABLE
The DISABLE command is used to turn off program features.
DISABLE DEBUG Stop simulating LLMOPs and use actual LLMOPs
DISABLE LOGGING Stop logging to a file.
DISABLE SPEAR-REPORTING Stop reporting to SPEAR.
DISABLE TRACE Stop showing program progress.
*ENABLE
The ENABLE command is used to enable any of the following features:
ENABLE DEBUG Simulate LLMOP calls for debugging.
ENABLE LOGGING filename All operator transactions enter filename.
ENABLE SPEAR-REPORTING Report to SPEAR on significant events.
ENABLE TRACE Show program progress for debugging.
*EXIT
The EXIT command is used to stop the program and return to monitor.
*IDENTIFY
The IDENTIFY command is used to receive a SYS-ID from the node specified
after the IDENTIFY command. The node must be a 12 DIGIT HEX ADDRESS.
Hyphens may be used.
*QUIT
The QUIT command is used to exit this program and return to monitor.
*READ-COUNTERS
The READ-COUNTERS command is followed by a 12 DIGIT HEX ADDRESS.
Hyphens may be used in the address. The counters of the specified node
are read and displayed.
*REDEFINE
The REDEFINE command is used to change the "disconnect" character. The
disconnect character is used when in the "remote-terminal" mode to
return to "command mode". The default disconnect character is
CONTROL-D.
*SET-PASSWORD
The SET-PASSWORD command is used to set the password of the node the
user wishes to be connected to. This password is used to gain access to
the remote console and must be specified before any CONNECT NODE
commands.
*SHOW
The SHOW command is used to find out the current status of any of the
following:
SHOW ALL Show all of the following except SHOW NODES.
SHOW DEBUG Show debug mode setting.
SHOW LOGGING Show log file setting and log file name.
SHOW NODES Show node addresses that respond to a multicast.
SHOW SPEAR-REPORTING Show SPEAR reporting flag.
SHOW TRACE Show program trace flag.
*TAKE
The TAKE command is followed by a filename which contains a sequence of
commands to be executed.
!End of RMTCON.HLP