Google
 

Trailing-Edge - PDP-10 Archives - ap-c800d-sb - bldcbl.log
There are 5 other files named bldcbl.log in the archive. Click here to see a list.
			26-Sep-79 11:27:18

BATCON Version	104(4126)			GLXLIB Version	1(515)
						Sequence Number 823

	    Job BLDCBL Req #118 for NIXON,D [10,131003] in Stream 0

	OUTPUT:	 Log				TIME-LIMIT: 0:05:00
	UNIQUE:	 Yes				BATCH-LOG:  Append
	RESTART: No				ASSISTANCE: Yes

	Input from File	CBL1:BLDCBL.CTL[10,131003]
	Output to  File	CBL1:BLDCBL.LOG[10,131003]



11:27:18 MONTR	.LOGIN 10/131003 /DEFER/SPOOL:ALL/TIME:300/ACCOUNT:/BATNAM:BLDCBL/BATSEQ:823/REQID:118/LOCATE:26/NAME:"NIXON,D"
11:27:18 USER	JOB 67     RZ376A KL #1026/1042 TTY501
11:27:19 USER	[LGNJSP Other jobs same PPN:30]
11:27:19 USER	%(1)LGNSLX Search list is empty
11:27:19 USER	11:27	26-Sep-79	Wed
11:27:19 USER	
11:27:19 USER	
11:27:19 USER	11-SEPT		A new version of MACRO.EXE is now on NEW:.
11:27:19 USER	
11:27:19 USER	20-sept		during the week of NOVEMBER 1 dskn will be
11:27:19 USER			removed permanatly from this system.  if you
11:27:19 USER			want any files on dskn: you should get them before
11:27:19 USER			then
11:27:19 USER						OPERATIONS
11:27:21 USER	CBL1: MOUNTED
11:27:21 MONTR	
11:27:21 MONTR	.
		!BLDCBL.CTL
		!
		!USED TO SUBMIT ALL THE .CTL FILES REQUIRED TO BUILD THE COBOL SYSTEM
		!THIS FILE RUNS ON EITHER TOPS-20 OR TOPS-10 ON ALL SUPPORTED MONITORS
		!SUBMIT WITH COMMAND	SUBMIT BLDCBL
		!
		!THIS SOFTWARE IS FURNISHED UNDER A LICENSE AND MAY ONLY BE USED
		!  OR COPIED IN ACCORDANCE WITH THE TERMS OF SUCH LICENSE.
		!
		!COPYRIGHT (C) 1979 BY DIGITAL EQUIPMENT CORPORATION
		!
		!IF ANY NON-STANDARD ASSEMBLY SWITCHES ARE DESIRED THEY SHOULD BE
		!	INSERTED IN COBASM.MAC
		!
		!INSTALLATION SPECIFIC ASSIGNMENTS SHOULD BE PUT IN THE FOLLOWING FILE:
		! ON TOPS-20 IN A TAKE FILE COBOL.CMD
		! ON TOPS-10 IN A MIC  FILE COBOL.MIC
		!	  OR IN A TECO FILE COBOL.TEC
		!IF THIS FILE IS ABSENT THEN ALL REQUIRED FILES ARE ASSUMED TO EXIST ON DSK:
		!
		!IF LISTINGS ARE DESIRED, THE EMPTY FILE
		!LISTEM.MAC SHOULD BE IN DSK:
		!
		!FOR COBOL-68 SET ANS68==1 AND ANS74==0 IN COBASM.MAC
		!FOR COBOL-74 SET ANS68==0 AND ANS74==1 IN COBASM.MAC
		!
		!IF A DEBUG VERSION IS REQUIRED
		!DEBUG==1 MUST BE IN COBASM.MAC
		!
		!IF A DBMS VERSION IS REQUIRED
		!DBMS==1 MUST BE IN COBASM.MAC
		!
		!TEST FOR WHICH SYSTEM
		@GOTO TOPS20	!TOPS20 VERSION
11:27:21 BATCH	.GOTO TOPS10	!TOPS10 VERSION
11:27:21 BLABL	TOPS10::
		!SEE IF WE NEED TO MODIFY THE CONTROL FILES FIRST
		!
11:27:21 MONTR	.TYPE COBOL.TEC
11:27:25 USER	.RUN DEC:SETSRC
11:27:25 USER	*LIB:[10,131001]
11:27:25 USER	.ASS LIB: SRC:
11:27:25 USER	.
11:27:25 MONTR	
11:27:25 MONTR	.
11:27:25 FALSE	.IF (ERROR) .GOTO NOMOD
		!
		!READ THE COBOL.TEC FILE IN A TECO Q REGISTER
11:27:25 MONTR	.R TECO
11:27:25 USER	
11:27:26 USER	**ERCOBOL.TEC^[AAAAAA^[HXA^[
11:27:26 USER	*ERCOBOL.CTL^[EWCOBOL.CTM^[Y^[<N.DO COBOL.MIC^[;0LK^[GA^[>^[HPEF^[
11:27:26 USER	*ERLIBOL.CTL^[EWLIBOL.CTM^[Y^[<N.DO COBOL.MIC^[;0LK^[GA^[>^[HPEF^[
11:27:26 USER	*ERCOBDDT.CTL^[EWCOBDDT.CTM^[Y^[<N.DO COBOL.MIC^[;0LK^[GA^[>^[HPEF^[
11:27:26 USER	*ERISAM.CTL^[EWISAM.CTM^[Y^[<N.DO COBOL.MIC^[;0LK^[GA^[>^[HPEF^[
11:27:26 USER	*ERLIBARY.CTL^[EWLIBARY.CTM^[Y^[<N.DO COBOL.MIC^[;0LK^[GA^[>^[HPEF^[
11:27:26 USER	*ERRERUN.CTL^[EWRERUN.CTM^[Y^[<N.DO COBOL.MIC^[;0LK^[GA^[>^[HPEF^[^[
11:27:26 USER	
11:27:26 USER	[2K Core]
11:27:44 USER	*
		!
		!SUBMIT CTM (MODIFIED CTL) FILES IN CORRECT ORDER
11:27:44 MONTR	
11:27:44 MONTR	..SUBMIT COBOL.CTM/TIME:1:0:0/RESTART:YES/DEPEND:0
11:27:45 USER	[Job COBOL Queued, Request-ID 119, Limit 1:00:00]
11:27:45 MONTR	
11:27:45 MONTR	..SUBMIT LIBOL.CTM/TIME:30:0/RESTART:YES/DEPEND:1
11:27:46 USER	[Job LIBOL Queued, Request-ID 120, Limit 0:30:00]
11:27:46 MONTR	
11:27:46 MONTR	..SUBMIT COBDDT.CTM/RESTART:YES/DEPEND:2
11:27:47 USER	[Job COBDDT Queued, Request-ID 121, Limit 0:05:00]
11:27:47 MONTR	
11:27:47 MONTR	..SUBMIT ISAM.CTM/RESTART:YES/DEPEND:3
11:27:48 USER	[Job ISAM Queued, Request-ID 122, Limit 0:05:00]
11:27:48 MONTR	
11:27:48 MONTR	..SUBMIT LIBARY.CTM/RESTART:YES/DEPEND:4
11:27:48 USER	[Job LIBARY Queued, Request-ID 123, Limit 0:05:00]
11:27:48 MONTR	
11:27:48 MONTR	..SUBMIT RERUN.CTM/RESTART:YES/DEPEND:5
11:27:49 USER	[Job RERUN Queued, Request-ID 124, Limit 0:05:00]
11:27:49 MONTR	
11:27:49 MONTR	.
11:27:49 BATCH	.GOTO OK
11:27:49 BLABL	OK::
		!END OF BLDCBL.CTL
11:27:49 MONTR	.KJOB/BATCH
11:27:49 USER	
11:27:49 USER	[LGTAJL Another job is still logged-in under [10,131003]]
11:27:50 MONTR	Job 67  User NIXON,D [10,131003]
11:27:50 MONTR	Logged-off TTY501  at 11:27:49  on 26-Sep-79
11:27:50 MONTR	Runtime: 0:00:04, KCS:39, Connect time: 0:00:31
11:27:50 MONTR	Disk Reads:581, Writes:189