TOPS20 Change Order Number 1738

Written by: HESS		16-Feb-77 10:32:32

Edit checked: YES			   Document: NO
  TCO Tested: YES		Maintenance Release: NO

Program: EDIT

Release: 3

Related TCO's:
Related SPR'S: 


Problem: 
	CERTAIN COMPATIBLE PROGRAMS CAN READ AN EXTRA TAB WHEN STIPPING
SEQUENCE NUMBERS.

Diagnosis: 
	EDIT BREAKS THE 6-CHARACTER SEQUENCE NUMBER ACROSS SECTOR
(200(8) WORD) BOUNDARIES. THIS IS BECAUSE EDIT USES 1 PAGE BUFFERS.

Solution: 
	CHECK FOR A SEQUENCE NUMBER IN THE LAST WORD OF A SECTOR AND
WRITE A WORD OF ZEROES IF SO. (ROUTINE "DUMP")
TOPS20 Change Order Number 1752

Written by: HESS		 7-Mar-77 11:53:25

Edit checked: YES			   Document: NO
  TCO Tested: YES		Maintenance Release: NO

Program: EDIT

Release: 3

Related TCO's:
Related SPR'S: 


Problem: 
	CERTAIN COPY/TRANSFER COMMANDS CREATE DUPLICATE LINE SEQUENCE
NUMBERS WHEN COPYING TO THE TOP OF A PAGE!

Diagnosis: 
	ROUTINE TWOSET IS NOT USING THE CORRECT INFORMATION FOR
CALCULATING THE INCREMENT IF THERE IS AN EXISTING LINE NUMBER ON THAT
PAGE.

Solution: 
	USE CORRECT ARGUMENTS TO GETDIF IN TWOSET.
TOPS20 Change Order Number 1767

Written by: HESS		 1-Apr-77 15:45:21

Edit checked: YES			   Document: NO
  TCO Tested: YES		Maintenance Release: NO

Program: EDIT

Release: 3

Related TCO's:
Related SPR'S: 


Problem: 
	A LOWER CASE "A" RANDOMLY APPEARS AS THE FIRST CHARACTER OF
A LINE.

Diagnosis: 
	IMPROPER USE OF A TEMPORARY LOCATION IN ORDCHK

Solution: 
	ADD SPECIAL CELL TO SAVE SEQUENCE # IN ORDCHK