TOPS20 Change Order Number 1738
Written by: HESS 16-Feb-77 10:32:32
Edit checked: YES Document: NO
TCO Tested: YES Maintenance Release: NO
Program: EDIT
Release: 3
Related TCO's:
Related SPR'S:
Problem:
CERTAIN COMPATIBLE PROGRAMS CAN READ AN EXTRA TAB WHEN STIPPING
SEQUENCE NUMBERS.
Diagnosis:
EDIT BREAKS THE 6-CHARACTER SEQUENCE NUMBER ACROSS SECTOR
(200(8) WORD) BOUNDARIES. THIS IS BECAUSE EDIT USES 1 PAGE BUFFERS.
Solution:
CHECK FOR A SEQUENCE NUMBER IN THE LAST WORD OF A SECTOR AND
WRITE A WORD OF ZEROES IF SO. (ROUTINE "DUMP")
TOPS20 Change Order Number 1752
Written by: HESS 7-Mar-77 11:53:25
Edit checked: YES Document: NO
TCO Tested: YES Maintenance Release: NO
Program: EDIT
Release: 3
Related TCO's:
Related SPR'S:
Problem:
CERTAIN COPY/TRANSFER COMMANDS CREATE DUPLICATE LINE SEQUENCE
NUMBERS WHEN COPYING TO THE TOP OF A PAGE!
Diagnosis:
ROUTINE TWOSET IS NOT USING THE CORRECT INFORMATION FOR
CALCULATING THE INCREMENT IF THERE IS AN EXISTING LINE NUMBER ON THAT
PAGE.
Solution:
USE CORRECT ARGUMENTS TO GETDIF IN TWOSET.
TOPS20 Change Order Number 1767
Written by: HESS 1-Apr-77 15:45:21
Edit checked: YES Document: NO
TCO Tested: YES Maintenance Release: NO
Program: EDIT
Release: 3
Related TCO's:
Related SPR'S:
Problem:
A LOWER CASE "A" RANDOMLY APPEARS AS THE FIRST CHARACTER OF
A LINE.
Diagnosis:
IMPROPER USE OF A TEMPORARY LOCATION IN ORDCHK
Solution: