Google
 

Trailing-Edge - PDP-10 Archives - bb-d868c-bm_tops20_v4_2020_distr - 4-documentation/setspd.tco
There are 21 other files named setspd.tco in the archive. Click here to see a list.
TOPS20 Change Order Number 4.1879

Written by: MILLER		16-Dec-77 13:45:03

Edit checked: YES			   Document: YES
  TCO Tested: YES		Maintenance Release: NO
Hardware-related: NO

Program: SETSPD

Related TCO's:
Related SPR's: 


Problem: NEED A COMMAD TO SET THE
DECNET HOST NAME

Diagnosis: AS ABOVE

Solution: ADD NODE COMMAND
TOPS20 Change Order Number 4.1993

Written by: R.ACE		24-Aug-78 11:53:24

Edit checked: YES			   Document: YES
  TCO Tested: YES		Maintenance Release: NO
Hardware-related: NO

Program: SETSPD

Related TCO's:
Related SPR's: 


Problem: NEED SETSPD COMMANDS TO CONTROL TAPE-DRIVE ALLOCATION

Diagnosis: 

Solution: IMPLEMENT NEW COMMAND FOR SETSPD:

ENABLE TAPE-DRIVE-ALLOCATION

SETS SYSTEM OPERATION MODE SO THAT TAPE DRIVES ARE ALLOCATED BY MTCON
AND NON-PRIVILEGED USERS MAY NOT ASSIGN OR OPEN MTA DEVICES.

IF THIS COMMAND IS OMITTED, THE SYSTEM WILL PERFORM (WITH RESPECT TO
TAPE DRIVE ALLOCATION) LIKE RELEASE 3 (NO LABELING, ETC.).
TOPS20 Change Order Number 4.2011

Written by: MILLER		17-Sep-78 13:50:50

Edit checked: NO			   Document: YES
  TCO Tested: NO		Maintenance Release: NO
Hardware-related: NO

Program: SETSPD

Related TCO's:
Related SPR's: 


Problem: Need support in SETSPD for scheduler controls

Diagnosis: 

Solution: Add new commands to SETSPD. Commands are described
in spec: ASM-78-002-02
TOPS20 Change Order Number 4.2098

Written by: R.ACE		28-Nov-78 07:50:49

Edit checked: NO			   Document: YES
  TCO Tested: NO		Maintenance Release: NO
Hardware-related: NO

Program: SETSPD

Related TCO's:	4.2088
Related SPR's: 


Problem: NEED SETSPD COMMANDS FOR SETTING SYSTEM-WIDE DEFAULTS FOR
MAGTAPE PROCESSING

Diagnosis: 

Solution: ADD "TAPE-MOUNT-DEFAULT" COMMAND TO SETSPD
[REFER TO PS:<DOC-SPECS>LTPROC.MEM FOR DESCRIPTION OF THIS COMMAND]
TOPS20 Change Order Number 4.2590

Written by: BLOUNT		 6-Dec-79 11:03:20

Edit checked: NO			   Document: NO
  TCO Tested: NO		Maintenance Release: NO
Hardware-related: YES

Program: SETSPD
   Routines Affected:	SETSPD

Related TCO's:
Related SPR's: 


Problem: THE KS-10 HALT STATUS BLOCK IS NOT SET UP CORRECTLY,
SO SYSERR GETS PASSED INCORRECT INFORMATION.  SEAN KEENAN
IS THE ORIGINATOR OF THIS PROBLEM AND SOLUTION.

Diagnosis: WRONG OFFSET USED IN INSTRUCTION

Solution: CHANGE (AT QUEDN1+7) "DMOVEM T1,HS%PC+4...."
TO "DMOVEM T1,HS%COD+4..."