Trailing-Edge
-
PDP-10 Archives
-
dec-10-omona-u-mc9
-
tty14d.mac
There are no other files named tty14d.mac in the archive.
SUBTTL TTYCNF - TERMINAL CONFIGURATION DEFINITION FILE OUTPUT BY MONGEN
DEFINE XP(A,B),<A==:B>
XP M.TTY,50
;; How many DC10s(1,0-2)[
;; The DC10 is a data line scanner]: 2 ;DC10'S
;; How many DC68s(1,0-2)[
;; The DC68 is a PDP-8 680 or 680I communications system]: 0 ;DC68'S
;; How many DC76s(1,0-8)[
;; The DC76 is a PDP-11 communications system]: 1 ;DC76'S
XP M.DC10,2
XP M.DC68,0
XP M.DC76,1
XP MD.DCS,0
;; # DC10B[ or 632] 8 line data groups(1-8)[
;; 1 is TTY0-7, 2 is TTY0 - 17, ... 8 is TTY0 - 77]: 7 ;DC10B
;; # DC10E Data set control groups(0-7): 1 ;DC10E
DEFINE MACCR0<
;; Correspondence of DC10E lines to the DC10B lines(M-N,P)[
;; Type M,P for one pair and M-N,P for a range of pairs
;; where M is octal DC10E line, M-N is octal range of DC10E
;; lines, and P is octal DC10B line]
;; 70-77,60 ;DC10E/DC10B CORRESPONDENCE
L 70,77,60
;;
>
;; # DC10B[ or 632] 8 line data groups(1-8)[
;; 1 is TTY0-7, 2 is TTY0 - 17, ... 8 is TTY0 - 77]: 2 ;DC10B
;; # DC10E Data set control groups(0-2): 0 ;DC10E
DEFINE MACCR1<
>
;; Which DL10 port is the DC76 connected to(0,1-7)[Each PDP-11
;; is connected to a DL10 port. If there is only one -11 it
;; is always connected to port 0. If there are 2 -11's one is
;; connected to port 0 and the other to port 1]: 1 ;DL10 PORT
;; Decimal lines on DC76(1-129)[
;; Each DC76F is 16 lines and the console teletype is
;; one line. A DC76 with 2 DC76Fs has 33 lines]: 80 ;DC76 LINES
XP M.D70N,0
XP M.D71N,120
XP M.D72N,0
XP M.D73N,0
XP M.D74N,0
XP M.D75N,0
XP M.D76N,0
XP M.D77N,0
XP M.TTG0,7
XP M.TTG1,2
XP M.DSG0,1
XP M.DSG1,0
XP M.68L0,0
XP M.68L1,0
XP M.TLTL,230 ;TOTAL LOCAL TTY LINES
;; OPR octal line #(CTY,0-227)[OPR is privileged operator terminal]: CTY ;OPR
DEFINE OPRLIN<
OPRL CTY
>
;; Answer the following questions about your TTY lines(M-N).
;; [Type one octal line #(M) or one range(M-N) or CTY on separate
;; lines. Type extra carriage return when through.]
DEFINE MACDSD<
;; Data set lines[Class of terminal for LOGIN, LOGIN resets line
;; to computer echoing and no hardware tabs]
;; 60-67 ;DATA SETS
L 60,67
;; 170-207 ;DC76 DATASETS
L 170,207
;;
>
DEFINE MACTAB<
;; Lines with hardware tabs[Monitor simulates rest with spaces]
;; 2-4
L 2,4
;; 10-23
L 10,23
;; 30-46
L 30,46
;; CTY
L CTY
;; CTY1
L CTY1
;;
>
DEFINE MACRMT<
;; Remote lines[Class of terminal for LOGIN, do not confuse
;; with remote station TTYs]
;; 2-330 ;REMOTE
L 2,330
;;
>
DEFINE MACLCP<
;; Local copy lines[Echoing provided by terminal rather than
;; by computer. Often (incorrectly) called half duplex]
;; ;LOCAL COPY
>
DEFINE MACHLF<
;; Half duplex lines[TWX or half duplex wired scanner(DC10C)]
;; ;HALF DUPLEX
>
DEFINE MACSLV<
;; Slaves[No commands may be typed]
;; ;SLAVES
>
DEFINE MACFRM<
;; Lines with hardware form feed[Leave out if users
;; would rather not get form feeds until they do TTY FORM commands]
;; ;FORM FEED
>
DEFINE MACINI<
;; Lines which run INITIA at startup
;; CTY
L CTY
;; CTY1
L CTY1
;; 0-7
L 0,7
;;
>
DEFINE MACFLC<
;; Filler class codes(M-N,P)[
;; Type M,P for one line M with filler class code P or
;; M-N,P for a range of lines with filler class code P]
;; 1,1 ;FILLER FOR VT06
L 1,1
;;
>
DEFINE MACDIS<
;; 2741 lines on DC-10 interfaces[]
;; 3 ;2741 INTERFACE LINE #
L 3
;;
>
;;
;; END OF TTY14D.MAC