Trailing-Edge
-
PDP-10 Archives
-
decus_20tap2_198111
-
decus/20-0026/load.ssp
There are 2 other files named load.ssp in the archive. Click here to see a list.
C LOAD 10
C ..................................................................LOAD 20
C LOAD 30
C SUBROUTINE LOAD LOAD 40
C LOAD 50
C PURPOSE LOAD 60
C COMPUTE A FACTOR MATRIX (LOADING) FROM EIGENVALUES AND LOAD 70
C ASSOCIATED EIGENVECTORS. THIS SUBROUTINE NORMALLY OCCURS LOAD 80
C IN A SEQUENCE OF CALLS TO SUBROUTINES CORRE, EIGEN, TRACE, LOAD 90
C LOAD, AND VARMX IN THE PERFORMANCE OF A FACTOR ANALYSIS. LOAD 100
C LOAD 110
C USAGE LOAD 120
C CALL LOAD (M,K,R,V) LOAD 130
C LOAD 140
C DESCRIPTION OF PARAMETERS LOAD 150
C M - NUMBER OF VARIABLES. LOAD 160
C K - NUMBER OF FACTORS. K MUST BE GREATER THAN OR EQUAL LOAD 170
C TO 1 AND LESS THAN OR EQUAL TO M. LOAD 171
C R - A MATRIX (SYMMETRIC AND STORED IN COMPRESSED FORM LOAD 180
C WITH ONLY UPPER TRIANGLE BY COLUMN IN CORE) CON- LOAD 190
C TAINING EIGENVALUES IN DIAGONAL. EIGENVALUES ARE LOAD 200
C ARRANGED IN DESCENDING ORDER, AND FIRST K LOAD 210
C EIGENVALUES ARE USED BY THIS SUBROUTINE. THE ORDER LOAD 220
C OF MATRIX R IS M BY M. ONLY M*(M+1)/2 ELEMENTS ARE LOAD 230
C IN STORAGE. (STORAGE MODE OF 1) LOAD 240
C V - WHEN THIS SUBROUTINE IS CALLED, MATRIX V (M X M) LOAD 250
C CONTAINS EIGENVECTORS COLUMNWISE. UPON RETURNING TOLOAD 260
C THE CALLING PROGRAM, MATRIX V CONTAINS A FACTOR LOAD 270
C MATRIX (M X K). LOAD 280
C LOAD 290
C REMARKS LOAD 300
C NONE LOAD 310
C LOAD 320
C SUBROUTINES AND FUNCTION SUBPROGRAMS REQUIRED LOAD 330
C NONE LOAD 340
C LOAD 350
C METHOD LOAD 360
C NORMALIZED EIGENVECTORS ARE CONVERTED TO THE FACTOR PATTERN LOAD 370
C BY MULTIPLYING THE ELEMENTS OF EACH VECTOR BY THE SQUARE LOAD 380
C ROOT OF THE CORRESPONDING EIGENVALUE. LOAD 390
C LOAD 400
C ..................................................................LOAD 410
C LOAD 420
SUBROUTINE LOAD (M,K,R,V) LOAD 430
DIMENSION R(1),V(1) LOAD 440
C LOAD 450
C ...............................................................LOAD 460
C LOAD 470
C IF A DOUBLE PRECISION VERSION OF THIS ROUTINE IS DESIRED, THE LOAD 480
C C IN COLUMN 1 SHOULD BE REMOVED FROM THE DOUBLE PRECISION LOAD 490
C STATEMENT WHICH FOLLOWS. LOAD 500
C LOAD 510
C DOUBLE PRECISION R,V,SQ LOAD 520
C LOAD 530
C THE C MUST ALSO BE REMOVED FROM DOUBLE PRECISION STATEMENTS LOAD 540
C APPEARING IN OTHER ROUTINES USED IN CONJUNCTION WITH THIS LOAD 550
C ROUTINE. LOAD 560
C LOAD 570
C THE DOUBLE PRECISION VERSION OF THIS SUBROUTINE MUST ALSO LOAD 580
C CONTAIN DOUBLE PRECISION FORTRAN FUNCTIONS. SQRT IN STATEMENT LOAD 590
C 150 MUST BE CHANGED TO DSQRT. LOAD 600
C LOAD 610
C ...............................................................LOAD 620
C LOAD 630
L=0 LOAD 640
JJ=0 LOAD 650
DO 160 J=1,K LOAD 660
JJ=JJ+J LOAD 670
150 SQ= SQRT(R(JJ)) LOAD 680
DO 160 I=1,M LOAD 690
L=L+1 LOAD 700
160 V(L)=SQ*V(L) LOAD 710
RETURN LOAD 720
END LOAD 730