TAPOUT.HLP
TAPOUT writes MAGtapes in foreign data formats. It does not write tape labels.
All type-ins may be in either upper or lower case.
TAPOUT never rewinds a tape. Positioning is up to you. Whenever TAPOUT
finishes writing a file to tape, it writes a double end-of-file mark, and
backspaces, so each file will have a file mark after it, and the last file
on the tape will have a double file mark.
Questions:
"Output device:" Logical or physical device name. Must be a MAGtape. Colon (:)
is optional.
If the tape is 7-track, the program will ask:
"Parity:" Normally EVEN for BCD tapes, else ODD. E or O is sufficient.
"Code:" ASCII (meaning 8-bit ASCII), BCD, EBCDIC, IMAGE, RSX11, or SIXBIT.
Typing the first letter will suffice. IMAGE writes binary data
(in industry mode if the tape is 9-track). If you specify ASCII,
the program will ask you whether you want 0 or 1 in the 8th bit,
and whether you want carriage return, line feed inserted after each
logical record.
"Record length:" The number of bytes per logical record. Usually 72, 80, 120 or
132.
"Blocking:" The number of logical records per physical block. Usually 1,
10 or 20. Try to make the number of bytes per block ( = logical
record multiplied by blocking factor) an exact multiple of 4 for
9-track tape, or 6 for 7-track (or 9-track SIXBIT). If necessary,
TAPOUT will fill out the last word with binary ones.
"Input device:" Logical or physical name. Colon (:) optional.
If the input device is a directory device, the program will ask:
"Filename.ext:" Type file name and extension, separated by a period (.).
If the input device is a MAGtape, the program will ask:
"How many files?". Give the number of consecutive files to be copied.
After the file has been written, the program will ask:
"More?" Reply Y if you want to write more files on this tape, else N.
Example:
.MO MTA:TAPE/WE/REEL:9999/V:9-TRK
Request queued
Waiting...2 ^C's to Exit
TAPE mounted, MTA015 used
.R TAPOUT
Output device: TAPE
[Output MAGtape density: 800, reel ID: 9999 ]
Code: EBCDIC
Record length: 80
Blocking: 10
Input device: DSK
Filename.ext: FOR20.DAT
[3+2P Core.]
[Copying.]
[End of file. 23 logical records, 3 blocks written.]
[0 soft write errors.]
[0 hard write errors.]
More? NO
EXIT
.DISMOUNT TAPE
[MTA015:9999 READ(C/H/S) = 11329/1/0 WRITE(C/H/S) = 1836/0/0]
MTA015 Dismounted