SUBROUTINE MCHB
PURPOSE
FOR A GIVEN POSITIVE-DEFINITE M BY M MATRIX A WITH SYMMETRIC
BAND STRUCTURE AND - IF NECESSARY - A GIVEN GENERAL M BY N
MATRIX R, THE FOLLOWING CALCULATIONS (DEPENDENT ON THE
VALUE OF THE DECISION PARAMETER IOP) ARE PERFORMED
(1) MATRIX A IS FACTORIZED (IF IOP IS NOT NEGATIVE), THAT
MEANS BAND MATRIX TU WITH UPPER CODIAGONALS ONLY IS
GENERATED ON THE LOCATIONS OF A SUCH THAT
TRANSPOSE(TU)*TU=A.
(2) MATRIX R IS MULTIPLIED ON THE LEFT BY INVERSE(TU)
AND/OR INVERSE(TRANSPOSE(TU)) AND THE RESULT IS STORED
IN THE LOCATIONS OF R.
THIS SUBROUTINE ESPECIALLY CAN BE USED TO SOLVE THE SYSTEM
OF SIMULTANEOUS LINEAR EQUATIONS A*X=R WITH POSITIVE-
DEFINITE COEFFICIENT MATRIX A OF SYMMETRIC BAND STRUCTURE.
USAGE
CALL MCHB (R,A,M,N,MUD,IOP,EPS,IER)
DESCRIPTION OF PARAMETERS
R - INPUT IN CASES IOP=-3,-2,-1,1,2,3 M BY N RIGHT
HAND SIDE MATRIX,
IN CASE IOP=0 IRRELEVANT.
OUTPUT IN CASES IOP=1,-1 INVERSE(A)*R,
IN CASES IOP=2,-2 INVERSE(TU)*R,
IN CASES IOP=3,-3 INVERSE(TRANSPOSE(TU))*R,
IN CASE IOP=0 UNCHANGED.
A - INPUT IN CASES IOP=0,1,2,3 M BY M POSITIVE-DEFINITE
COEFFICIENT MATRIX OF SYMMETRIC BAND STRUC-
TURE STORED IN COMPRESSED FORM (SEE REMARKS),
IN CASES IOP=-1,-2,-3 M BY M BAND MATRIX TU
WITH UPPER CODIAGONALS ONLY, STORED IN
COMPRESSED FORM (SEE REMARKS).
OUTPUT IN ALL CASES BAND MATRIX TU WITH UPPER
CODIAGONALS ONLY, STORED IN COMPRESSED FORM
(THAT MEANS UNCHANGED IF IOP=-1,-2,-3).
M - INPUT VALUE SPECIFYING THE NUMBER OF ROWS AND
COLUMNS OF A AND THE NUMBER OF ROWS OF R.
N - INPUT VALUE SPECIFYING THE NUMBER OF COLUMNS OF R
(IRRELEVANT IN CASE IOP=0).
MUD - INPUT VALUE SPECIFYING THE NUMBER OF UPPER
CODIAGONALS OF A.
IOP - ONE OF THE VALUES -3,-2,-1,0,1,2,3 GIVEN AS INPUT
AND USED AS DECISION PARAMETER.
EPS - INPUT VALUE USED AS RELATIVE TOLERANCE FOR TEST ON
LOSS OF SIGNIFICANT DIGITS.
IER - RESULTING ERROR PARAMETER CODED AS FOLLOWS
IER=0 - NO ERROR,
IER=-1 - NO RESULT BECAUSE OF WRONG INPUT
PARAMETERS M,MUD,IOP (SEE REMARKS),
OR BECAUSE OF A NONPOSITIVE RADICAND AT
SOME FACTORIZATION STEP,
OR BECAUSE OF A ZERO DIAGONAL ELEMENT
AT SOME DIVISION STEP.
IER=K - WARNING DUE TO POSSIBLE LOSS OF SIGNIFI-
CANCE INDICATED AT FACTORIZATION STEP K+1
WHERE RADICAND WAS NO LONGER GREATER
THAN EPS*A(K+1,K+1).
REMARKS
UPPER PART OF SYMMETRIC BAND MATRIX A CONSISTING OF MAIN
DIAGONAL AND MUD UPPER CODIAGONALS (RESP. BAND MATRIX TU
CONSISTING OF MAIN DIAGONAL AND MUD UPPER CODIAGONALS)
IS ASSUMED TO BE STORED IN COMPRESSED FORM, I.E. ROWWISE
IN TOTALLY NEEDED M+MUD*(2M-MUD-1)/2 SUCCESSIVE STORAGE
LOCATIONS. ON RETURN UPPER BAND FACTOR TU (ON THE LOCATIONS
OF A) IS STORED IN THE SAME WAY.
RIGHT HAND SIDE MATRIX R IS ASSUMED TO BE STORED COLUMNWISE
IN N*M SUCCESSIVE STORAGE LOCATIONS. ON RETURN RESULT MATRIX
INVERSE(A)*R OR INVERSE(TU)*R OR INVERSE(TRANSPOSE(TU))*R
IS STORED COLUMNWISE TOO ON THE LOCATIONS OF R.
INPUT PARAMETERS M, MUD, IOP SHOULD SATISFY THE FOLLOWING
RESTRICTIONS MUD NOT LESS THAN ZERO,
1+MUD NOT GREATER THAN M,
ABS(IOP) NOT GREATER THAN 3.
NO ACTION BESIDES ERROR MESSAGE IER=-1 TAKES PLACE IF THESE
RESTRICTIONS ARE NOT SATISFIED.
THE PROCEDURE GIVES RESULTS IF THE RESTRICTIONS ON INPUT
PARAMETERS ARE SATISFIED, IF RADICANDS AT ALL FACTORIZATION
STEPS ARE POSITIVE AND/OR IF ALL DIAGONAL ELEMENTS OF
UPPER BAND FACTOR TU ARE NONZERO.
SUBROUTINES AND FUNCTION SUBPROGRAMS REQUIRED
NONE
METHOD
FACTORIZATION IS DONE USING CHOLESKY-S SQUARE-ROOT METHOD,
WHICH GENERATES THE UPPER BAND MATRIX TU SUCH THAT
TRANSPOSE(TU)*TU=A. TU IS RETURNED AS RESULT ON THE
LOCATIONS OF A. FURTHER, DEPENDENT ON THE ACTUAL VALUE OF
IOP, DIVISION OF R BY TRANSPOSE(TU) AND/OR TU IS PERFORMED
AND THE RESULT IS RETURNED ON THE LOCATIONS OF R.
FOR REFERENCE, SEE H. RUTISHAUSER, ALGORITHMUS 1 - LINEARES
GLEICHUNGSSYSTEM MIT SYMMETRISCHER POSITIV-DEFINITER
BANDMATRIX NACH CHOLESKY - , COMPUTING (ARCHIVES FOR
ELECTRONIC COMPUTING), VOL.1, ISS.1 (1966), PP.77-78.