Trailing-Edge
-
PDP-10 Archives
-
k20v7b
-
mfg/cmds/mh10p6.cmd
There are no other files named mh10p6.cmd in the archive.
; MH10P6.CMD VER:0.1 22-JAN-79 M.L.R. 27911
;
; MH10 CHECKOUT PROCEDURE PART 6.
;
; INTERLEAVE TEST.
;
; *** CABLE TWO MH10'S TOGETHER!
; *** SET LOWER BOUND ADDRESS SWITCHES 34 AND 35 TO INTL
; ON BOTH MH'S
; *** IF BOTH MH'S HAVE 256K OF CORE SET LOWER BOUND
; ADDRESS SWITCH 17 ON MH 1 TO A 1.
;
; TYPE JC WHEN YOU ARE READY!
;
SP
; *** ZERO OUT CORE!
;
; *** DEPOSIT ALL 1'S IN 4 CONSECUTIVE LOCATIONS
; STARTING AT LOC 1000!
;
;
; *** VERIFY THAT THE ADDRESS INDICATORS FOR C0 IN THE
; LOW MH SHOW 1000 AND THE DATA IS ALL 1'S!
;
; *** VERIFY THAT THE ADDRESS INDICATORS FOR C1 IN THE
; LOW MH SHOW 1001 AND THE DATA IS ALL 1'S!
;
; *** VERIFY THAT THE ADDRESS INDICATORS FOR C0 IN THE
; HIGH MH SHOW 1002 AND THE DATA IS ALL 1'S!
;
; *** VERIFY THAT THE ADDRESS INDICATORS FOR C1 IN THE
; HIGH MH SHOW 1003 AND THE DATA IS ALL 1'S!
;
;
; TYPE JC WHEN YOU ARE READY TO CONTINUE!
SP
J 62.CMD