Google
 

Trailing-Edge - PDP-10 Archives - k20v7b - mfg/cmds/mh10p6.cmd
There are no other files named mh10p6.cmd in the archive.
;	MH10P6.CMD VER:0.1  22-JAN-79  M.L.R. 27911
;
;	MH10 CHECKOUT PROCEDURE PART 6.
;
;	INTERLEAVE TEST.
;
;		*** CABLE TWO MH10'S TOGETHER!
;		*** SET LOWER BOUND ADDRESS SWITCHES 34 AND 35 TO INTL 
;			ON BOTH MH'S
;		*** IF BOTH MH'S HAVE 256K OF CORE SET LOWER BOUND
;			ADDRESS SWITCH 17 ON MH 1 TO A 1.
;
;	TYPE JC WHEN YOU ARE READY!
;
SP
;		*** ZERO OUT CORE!
;
;		*** DEPOSIT ALL 1'S IN 4 CONSECUTIVE LOCATIONS
;			STARTING AT LOC 1000!
;
;
;		*** VERIFY THAT THE ADDRESS INDICATORS FOR C0 IN THE
;			LOW MH SHOW 1000 AND THE DATA IS ALL 1'S!
;
;		*** VERIFY THAT THE ADDRESS INDICATORS FOR C1 IN THE
;			LOW MH SHOW 1001 AND THE DATA IS ALL 1'S!
;
;		*** VERIFY THAT THE ADDRESS INDICATORS FOR C0 IN THE
;			HIGH MH SHOW 1002 AND THE DATA IS ALL 1'S!
;
;		*** VERIFY THAT THE ADDRESS INDICATORS FOR C1 IN THE 
;			HIGH MH SHOW 1003 AND THE DATA IS ALL 1'S!
;
;
;	TYPE JC WHEN YOU ARE READY TO CONTINUE!
SP
J 62.CMD